Intel S2600GZ S2600GZ/GL - Page 230
Table 55. BMC Core Sensors
View all Intel S2600GZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 230 highlights
Intel® Server Board S2600GZ/GL TPS Appendix B: Integrated BMC Sensor Tables Note: All sensors listed below may not be present on all platforms. Please check platform EPS section for platform applicability and platform chassis section for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply) Full Sensor Name (Sensor name in SDR) Sensor Platform # Applicability Power Unit Status (Pwr Unit Status) 01h All Power Unit RedundancyNote1 (Pwr Unit Redund) 02h Chassisspecific Table 55. BMC Core Sensors Sensor Type Event/Readi Event Offset Triggers ng Type Power Unit 09h Sensor Specific 6Fh 00 - Power down 02 - 240 VA power down 04 - A/C lost 05 - Soft power control failure Contrib. To System Status OK Assert/ De- assert Readable Value/Of fsets Event Data Fatal OK Fatal As and - Trig Offset De 06 - Power unit failure 00 - Fully Redundant OK Rearm A Standby X 01 - Redundancy lost Degraded 02 - Redundancy degraded Degraded Power Unit 03 - Non-redundant: Generic sufficient resources. Degraded As and - Trig Offset A X 09h 0Bh Transition from full De redundant state. 04 - Non-redundant: sufficient resources. Transition from insufficient state. Degraded 05 - Non-redundant: insufficient resources Fatal Revision 1.1 217 Intel order number G24881-004