Intel S2600GZ S2600GZ/GL - Page 78

Set LAN Configuration Parameter, IP Address Source, IP Address, Internet, Standard Subnetting

Page 78 highlights

Intel® Server Board S2600GZ/GL TPS Platform Management Functional Overview 6.10.3.5 BMC IP Address Configuration Enabling the BMC's network interfaces requires using the Set LAN Configuration Parameter command to configure LAN configuration parameter 4, IP Address Source. The BMC supports this parameter as follows:  1h, static address (manually configured): Supported on all management NICs. This is the BMC's default value.  2h, address obtained by BMC running DHCP: Supported only on embedded management NICs. IP Address Source value 4h, address obtained by BMC running other address assignment protocol, is not supported on any management NIC. Attempting to set an unsupported IP address source value has no effect, and the BMC returns error code 0xCC, Invalid data field-in request. Note that values 0h and 3h are no longer supported, and will return a 0xCC error completion code. 6.10.3.5.1 Static IP Address (IP Address Source Values 0h, 1h, and 3h) The BMC supports static IP address assignment on all of its management NICs. The IP address source parameter must be set to "static" before the IP address; the subnet mask or gateway address can be manually set. The BMC takes no special action when the following IP address source is specified as the IP address source for any management NIC:  1h - Static address (manually configured) The Set LAN Configuration Parameter command must be used to configure LAN configuration parameter 3, IP Address, with an appropriate value. The BIOS does not monitor the value of this parameter, and it does not execute DHCP for the BMC under any circumstances, regardless of the BMC configuration. 6.10.3.5.2 Static LAN Configuration Parameters When the IP Address Configuration parameter is set to 01h (static), the following parameters may be changed by the user:  LAN configuration parameter 3 (IP Address)  LAN configuration parameter 6 (Subnet Mask)  LAN configuration parameter 12 (Default Gateway Address) When changing from DHCP to Static configuration, the initial values of these three parameters will be equivalent to the existing DHCP-set parameters. Additionally, the BMC observes the following network safety precautions: 1. The user may only set a subnet mask that is valid, per IPv4 and RFC 950 (Internet Standard Subnetting Procedure). Invalid subnet values return a 0xCC (Invalid Data Field in Request) completion code, and the subnet mask is not set. If no valid mask has been previously set, default subnet mask is 0.0.0.0. 2. The user may only set a default gateway address that can potentially exist within the subnet specified above. Default gateway addresses outside the BMC's subnet are Revision 1.1 65 Intel order number G24881-004

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264

Intel® Server Board S2600GZ/GL TPS
Platform Management Functional Overview
Revision 1.1
Intel order number G24881-004
65
6.10.3.5
BMC IP Address Configuration
Enabling the BMC’s network interfaces requires using the
Set LAN Configuration Parameter
command to configure LAN configuration parameter 4,
IP Address Source
. The BMC supports
this parameter as follows:
1h, static address (manually configured): Supported on all management NICs. This is the
BMC’s default value.
2h, address obtained by BMC running DHCP: Supported only on embedded management
NICs.
IP Address Source value 4h, address obtained by BMC running other address assignment
protocol, is not supported on any management NIC.
Attempting to set an unsupported IP address source value has no effect, and the BMC returns
error code 0xCC, Invalid data field-in request. Note that values 0h and 3h are no longer
supported, and will return a 0xCC error completion code.
6.10.3.5.1
Static IP Address (IP Address Source Values 0h, 1h, and 3h)
The BMC supports static IP address assignment on all of its management NICs. The IP address
source parameter must be set to “static” before the IP addre
ss; the subnet mask or gateway
address can be manually set.
The BMC takes no special action when the following IP address source is specified as the IP
address source for any management NIC:
1h
Static address (manually configured)
The
Set LAN Configuration Parameter
command must be used to configure LAN configuration
parameter 3,
IP Address
, with an appropriate value.
The BIOS does not monitor the value of this parameter, and it does not execute DHCP for the
BMC under any circumstances, regardless of the BMC configuration.
6.10.3.5.2
Static LAN Configuration Parameters
When the IP Address Configuration parameter is set to 01h (static), the following parameters
may be changed by the user:
LAN configuration parameter 3 (IP Address)
LAN configuration parameter 6 (Subnet Mask)
LAN configuration parameter 12 (Default Gateway Address)
When changing from DHCP to Static configuration, the initial values of these three parameters
will be equivalent to the existing DHCP-set parameters. Additionally, the BMC observes the
following network safety precautions:
1.
The user may only set a subnet mask that is valid, per IPv4 and RFC 950 (
Internet
Standard Subnetting Procedure
). Invalid subnet values return a 0xCC (Invalid Data Field
in Request) completion code, and the subnet mask is not set. If no valid mask has been
previously set, default subnet mask is 0.0.0.0.
2.
The user may only set a default gateway address that can potentially exist within the
subnet specified above. Default gateway addresses outside the BMC’s subnet are