Cisco III System Message Guide - Page 52
hw-module, fan-tray version 2
UPC - 746320181691
View all Cisco III manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
C6KENV Messages Chapter 2 Messages and Recovery Procedures Error Message %C6KENV-4-FANHIOUTPUT: Version [dec] high-output fan-tray is in effect Explanation The system has detected that the fan tray is a high-output (version 2) fan tray. The system has updated the cooling capacity for the fan tray. Recommended Action No action is required. Error Message %C6KENV-4-FANLOOUTPUT: Version [dec] low-output fan-tray is in effect Explanation The system has detected that the fan tray is a low-output (version 1) fan tray. The system has updated the cooling capacity for the fan tray. Recommended Action No action is required. Error Message %C6KENV-4-FANPSINCOMPAT: Fan tray and power supply [dec] are incompatible Explanation An upgrade of the power supply is required to sufficiently operate this fan tray. Although this is a minor alarm, overcurrent protection on the power supply could start without further warning. Recommended Action Upgrade the power supply. Error Message %C6KENV-4-FANVERCHK: Power-supply [dec] inserted is only compatible with Version [dec] fan-tray. Please make sure fan is low-output fan-tray Explanation The system has detected that the fan tray is a low-output (version 1) fan tray. If the fan tray is a low-output tray, no action is required. If the fan tray is actually a high-output (version 2) fan tray, the specified power supply is not able to support the high-output fan tray. Recommended Action If the fan tray is a high-output (version 2) fan tray, enter the hw-module fan-tray version 2 command to update the system with the upgrade information. Replace the 1000 W or 1300 W power supply, as these two power supplies are not compatible in this chassis with the version 2 fan tray. Error Message %C6KENV-4-INSUFFCOOL: Module [dec] cannot be adequately cooled Explanation The fan tray cannot adequately cool the specified module. Although this is a minor alarm, system components could overheat and be shut down. Recommended Action Upgrade the system fan tray. Error Message %C6KENV-4-MINORTEMPOKALARM: [chars] all temperature sensor have failed. If the module temperature sensor does not recover by itself, please power cycle the module when it is feasible Explanation All module temperature sensors have failed. Recommended Action If the module temperature sensors do not recover, power cycle the module when possible. 2-22 Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY OL-11469-02