C6KPWR Messages Chapter 2 Messages and Recovery Procedures C6KPWR Messages This section contains Catalyst 6500 series switch and Cisco 7600 series router power (C6KPWR) messages. C6KPWR-2 Error Message %C6KPWR-2-INSUFFICIENTPOWER: Powering down all linecards as there is not enough power to operateall critical cards Explanation The switch was operating with two power supplies in combined mode. One of the power supplies has failed. Available power is insufficient to support all critical service modules. Critical service modules include modules that support VPNs or IP security. If these critical modules fail, security issues could arise; therefore, all modules have been powered down. Recommended Action Replace the failed power supply. Error Message %C6KPWR-2-MAJORPOWERALARM: In the absence of power supply 1, system power usage exceeds allowed range of [chars]W. Power total will be reduced in [dec] seconds Explanation The power supply in slot 2 has exceeded its allowed range, causing a major power alarm. The range is specified in the error message. Recommended Action Enter the show power command to determine the actual power usage. Insert a power supply in power supply slot 1, or power down some modules to reduce system power usage. If downtime can be scheduled, move the power supply from slot 2 to slot 1. If this condition persists, the environmental monitor will shut down some modules to prevent a complete power failure. Error Message %C6KPWR-2-MAJORPOWERALARMRECOVER: System power usage has returned to allowed operating range Explanation System power usage has returned to the permitted operating range. The scheduled shutdown is cancelled, and the system will continue operating. Recommended Action No action is required. Error Message %C6KPWR-2-MINORPOWERALARM: In the absence of power supply 1, system power usage exceeds the recommended range of [chars]W Explanation The power supply in slot 2 has exceeded its allowed range, causing a minor power alarm. The range is specified in the error message. Selected modules will be shut down to prevent a complete power failure. Recommended Action Enter the show power command to determine the actual power usage. Insert a power supply in power supply slot 1, or power down some modules to reduce system power usage. If downtime can be scheduled, move the power supply from slot 2 to slot 1. 2-24 Catalyst Supervisor Engine 32 PISA Cisco IOS System Message Guide, Release 12.2ZY OL-11469-02