Installing the second drive bay assembly, Removing the second drive bay assembly

Page 89 highlights

Figure 64. Removing the second drive bay assembly Next steps Replace the second drive bay assembly. Installing the second drive bay assembly Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. 3. If removed, install the drive backplane. 4. If removed, install the RAID controller card. 5. If applicable, reconnect cables to the RAID controller. Steps 1. Holding the edges or the touch points, align the holes on the riser bracket with the guides on the chassis. 2. Lower the whole assembly into place and press the touch points until it is fully seated in place. 3. Tighten the one blue thumb screw located at the front of the assembly, and two blue thumb screws located at the rear of the assembly. Installing and removing system components 89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177

Figure 64. Removing the second drive bay assembly
Next steps
Replace the second drive bay assembly
.
Installing the second drive bay assembly
Prerequisites
1.
Follow the safety guidelines listed in the
Safety instructions
.
2.
Follow the procedure listed in the
Before working inside your system
.
3.
If removed,
install the drive backplane
.
4.
If removed,
install the RAID controller card
.
5.
If applicable, reconnect cables to the RAID controller.
Steps
1.
Holding the edges or the touch points, align the holes on the riser bracket with the guides on the chassis.
2.
Lower the whole assembly into place and press the touch points until it is fully seated in place.
3.
Tighten the one blue thumb screw located at the front of the assembly, and two blue thumb screws located at the rear of
the assembly.
Installing and removing system components
89