FS700TS Smart Switch Software Administration Manual Basic The PoE Basic menu contains the following option: • "PoE Configuration" PoE Configuration The Basic PoE Configuration screen contains system PoE information for enabling PoE on the device, monitoring the current power usage, and enabling PoE traps. To configure PoE on the device: 1. Click System > PoE > Basic > PoE Configuration. The Basic PoE Configuration screen displays: Figure 3-9 The Basic PoE Configuration screen contains the following fields: • Unit ID - Displays the online power unit ID. • Power Status - Displays the online power source status. The possible field values are: - On - The power supply unit is functioning. - Off - The power supply unit is not functioning. - Faulty - The power supply unit is functioning, but an error has occurred. For example, a power overload or a short circuit. • Nominal Power - Displays the actual amount of power the device can supply. The field value is displayed in Watts. • Consumed Power - Displays the amount of the power used by the device. The field value is displayed in Watts. Managing System Settings v1.0, September 2007 3-17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

FS700TS Smart Switch Software Administration Manual
Managing System Settings
3-17
v1.0, September 2007
Basic
The PoE
Basic
menu contains the following option:
“PoE Configuration”
PoE Configuration
The Basic PoE Configuration screen contains system PoE information for enabling PoE on the
device, monitoring the current power usage, and enabling PoE traps.
To configure PoE on the device:
1.
Click
System > PoE > Basic > PoE Configuration
. The Basic PoE Configuration screen
displays:
The Basic PoE Configuration screen contains the following fields:
Unit ID
– Displays the online power unit ID.
Power Status
– Displays the online power source status. The possible field values are:
On – The power supply unit is functioning.
Off – The power supply unit is not functioning.
Faulty – The power supply unit is functioning, but an error has occurred. For example,
a power overload or a short circuit.
Nominal Power
– Displays the actual amount of power the device can supply. The field
value is displayed in Watts.
Consumed Power
– Displays the amount of the power used by the device. The field value
is displayed in Watts.
Figure 3-9