Asus SCSI 320-0 Global Array Manager Transition Tool - Page 121

Enclosure Management Icons, Alarm Control, Description, Setting

Page 121 highlights

Adapter Menu, Continued Enclosure Management Icons The status of the power supply, fans, and temperature for SAFTE compliant subsystems appears when you click on one of the icons: Icon Description Displays the current status of the power supply in the enclosure for the selected subsystem. Displays the current status of the cooling fans in the enclosure for the selected subsystem. Displays the current temperature of the enclosure for the selected subsystem. Alarm Control The alarm generates a beeping sound when one or more disks fail. The sound continues until Silence Alarm is selected. After a rebuild finishes, a beep signals that the rebuild is done. Choose Silence Alarm at this time to silence the alarm. The alarm settings are: Setting Enable/ Disable Alarm Silence Alarm Description Enables the alarm. If Disable Alarm appears, the alarm is enabled. If Enable Alarm appears, the alarm is disabled. When Enable Alarm is set, a beeping sound occurs even when all logical drives are online and there are no failed disks after a hot spare rebuild completes. Use the Silence Alarm function to stop the alarm. The normal setting should be Enable Alarm. Stops the alarm if it is currently beeping. If the alarm is not beeping, it has no effect. There is no normal setting. It acts as a temporary switch. Chapter 6 Running Power Console Plus 113

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154

Chapter 6 Running Power Console Plus
113
Adapter Menu,
Continued
Enclosure Management Icons
The status of the power supply, fans, and temperature for SAF-
TE compliant subsystems appears when you click on one of the icons:
Icon
Description
Displays the current status of the power supply in the
enclosure for the selected subsystem.
Displays the current status of the cooling fans in the
enclosure for the selected subsystem.
Displays the current temperature of the enclosure for the
selected subsystem.
Alarm Control
The alarm generates a beeping sound when one or more disks fail. The sound
continues until
Silence Alarm
is selected. After a rebuild finishes, a beep signals
that the rebuild is done. Choose
Silence Alarm
at this time to silence the alarm.
The alarm settings are:
Setting
Description
Enable/
Disable
Alarm
Enables the alarm. If Disable Alarm appears, the alarm is enabled. If Enable Alarm
appears, the alarm is disabled. When Enable Alarm is set, a beeping sound occurs
even when all logical drives are online and there are no failed disks after a hot spare
rebuild completes. Use the Silence Alarm function to stop the alarm. The normal
setting should be Enable Alarm.
Silence
Alarm
Stops the alarm if it is currently beeping. If the alarm is not beeping, it has no effect.
There is no normal setting. It acts as a temporary switch.