HP Z210 HP Z210 CMT Workstation Maintenance and Service Guide - Page 156
HP Z210 Manual
View all HP Z210 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 156 highlights
Table 6-9 POST error messages (continued) Screen message Probable cause Recommended action 914- Hood Lock Coil is not Connected Mechanism is missing or is not connected. 1. Reconnect or replace the missing mechanism. 2. Reseat or replace the missing mechanism cable. 916-Power Button Not Connected Power button cable is disconnected from the system board. Reconnect the cable and restart. 917-Front Audio Not Connected Front Audio mechanism is missing or is 1. Replace or reconnect the missing front audio not connected. mechanism to the system board. 2. Reseat or replace the missing mechanism cable. 918-Front USB Not Connected Front USB mechanism is missing or is not connected. 1. Replace or reconnect the missing Front USB mechanism to the system board. 2. Reseat or replace the missing mechanism cable. 919-Multi-Bay Riser Not Connected Multi-Bay riser mechanism is missing or is not connected. 1. Replace or reconnect the missing Multi-Bay mechanism to the system board. 2. Reseat or replace the missing mechanism cable. 920-Fatal error on QPI link X Fatal error detected on QPI link x, where x is 0 or 1. This type of error is identified on the line following the error message. Potential system board problem; contact HP Support. 921-Fatal error on QPI Protocol link X Fatal error detected in QPI link x protocol, where x is 0 or 1. This type of error is identified on the line following the error message. Potential system board problem; contact HP Support. 922-Fatal error on PCIe slot Fatal error occurred in the designated Move the card to a different slot. If the problem X slot. persists, replace the card. 923-Fatal error on ESI port 0 A fatal error occurred on ESI port 0. slot. Verify that the ESI port device is connected and working properly. 924-Fatal error on IOH core X Fatal error detected on IOH core x, where x is 0 or 1. This type of error is identified on the line following. Potential system board problem; contact HP Support. 925-Fatal error on IOH miscellaneous Fatal miscellaneous error detected on IOH core x, where x is 0 or 1. Potential system board problem; contact HP Support. 926-Fatal error on IOH Vtd Fatal error detected in the Intel Virtualization Technology. Potential system board problem; contact HP Support. 927-Fatal error on DIMM in slot CPU X DIMM Y Fatal multibit ECC error detected on the DIMM in the slot labeled DIMM x (where x is 1 - 4), as labeled on the system board. Replace the DIMM in the identified slot. 928-Fatal machine check detected on CPU X Contact HP support. 144 Chapter 6 Diagnostics and troubleshooting ENWW