HP Z210 HP Z210 CMT Workstation Maintenance and Service Guide - Page 21
Power supply specifications, Power consumption and heat dissipation, To reach zero power consumption - review
View all HP Z210 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Power supply specifications Table 1-6 Power supply specifications Item Description Power supply 400W Wide Ranging, Active PFC and 90% efficient at typical loads Operating voltage range 90-269 VAC Rated voltage range 100-240 VAC Rated line frequency 50-60 Hz Operating line frequency range 47-63 Hz Rated input current 6A @ 100-127 VAC 3A @ 200-240 VAC Heat dissipation (Configuration and software dependent) Typical: 985 btu/hr Maximum 1569BTU/hr = (395.4 kg-cal/hr) Power supply fan One fan, 92mm x 25mm, variable speed ENERGY STAR Qualified (Config dependent) Yes 80 PLUS® Compliant Yes, Gold-level rating FEMP Standby Power compliant @115V (
Power supply specifications
Table 1-6
Power supply specifications
Item
Description
Power supply
400W Wide Ranging, Active PFC and 90% efficient at typical
loads
Operating voltage range
90–269 VAC
Rated voltage range
100–240 VAC
Rated line frequency
50–60 Hz
Operating line frequency range
47–63 Hz
Rated input current
6A @ 100-127 VAC
3A @ 200–240 VAC
Heat dissipation
(Configuration and software dependent)
Typical: 985 btu/hr
Maximum 1569BTU/hr = (395.4 kg-cal/hr)
Power supply fan
One fan, 92mm x 25mm, variable speed
ENERGY STAR Qualified (Config dependent)
Yes
80 PLUS® Compliant
Yes, Gold-level rating
FEMP Standby Power compliant @115V (<2W in
S5 – Power Off)
Yes
ERP Lot 6 Tier 1 Compliant@ 230V (<1W in S5
– Power Off)
Yes
ERP Lot 6 Tier 2 Compliant @ 230V (<0.5W in
S5 – Power Off)
Yes
Built-in Self Test LED
Yes
Surge tolerant full ranging power supply
(withstands power surges up to 2000V)
Yes
Power Consumption in sleep mode (as defined
by ENERGY STAR) - Suspend to RAM (S3)
(Instantly Available PC)
<4W
Power consumption and heat dissipation
Power consumption and heat dissipation specifications are available for multiple configurations. To
review available specifications, see
go/quickspecs
.
To reach zero power consumption, unplug the workstation from the power outlet or use a power strip
with an on/off switch. For additional information about power-saving features, see the operating system
installation instructions.
This product is in compliance with U.S. Executive Order 13221.
ENWW
Workstation specifications
9