HP Xw4550 HP xw4550 Workstation - Service and Technical Reference Guide - Page 130
POST error messages, continued, Screen message, Probable cause, Recommended action
UPC - 883585505951
View all HP Xw4550 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
Table 5-18 POST error messages (continued) Screen message Probable cause Recommended action 514-CPU or Chassis Fan not Processor fan is not connected or detected might have malfunctioned. 1. Reseat the processor or chassis fan. 2. Replace the processor or chassis fan. 601-Diskette Controller Error Diskette controller circuitry or diskette 1. Run the Computer Setup (F10) Utility. drive circuitry incorrect. 2. Verify and replace cables. 3. Clear CMOS. 4. Replace diskette drive. 5. Replace the system board. 605-Diskette Drive Type Error Mismatch in drive type. 1. Run the Computer Setup (F10) Utility. 2. Disconnect any other diskette controller devices (tape drives). 3. Clear CMOS. 611-Primary Diskette Port Configuration error. Address Assignment Conflict 1. Run the Computer Setup (F10) Utility. 2. Remove expansion cards. 3. Clear CMOS. 912-Computer Cover Has N/A Been Removed Since Last System Start Up No action required. 914-Hood Lock Coil is not Connected Hood lock mechanism is missing or not 1. Reconnect or replace hood locking mechanism. connected. 2. Reseat or replace hood locking mechanism cable. 916-Power Button Not Connected The power button is not connected. Connect power button. 917-Front Audio Not Connected The front audio cable is not connected. Connect front audio cable. 918-Front USB Not Connected Front USB is not connected. Connect front USB cable. 919-MultiBay Riser Not Connected MultiBay riser is not connected. Connect MultiBay riser. 960-Processor Overtemp occurred The ambient temperature could 1. Be sure you are not operating the system in an exceed operating limits environment that exceeds 95oF (35oC). (maximum=95oF, 35oC), or there are obstructions to airflow, including dust 2. Disconnect power and open the access panel. build up. 3. Verify that cables are not blocking processor heatsink fans or front fan, if installed. 4. Verify that there is not excessive dust on major components. 5. If airflow is acceptable and there is not excessive dust, the thermal sensing circuitry has failed on the processors or on the system board. You must replace the processors and/or the system board. 1151-Serial Port 1 Address Conflict Detected Both external and internal serial ports 1. Remove any Comm port expansion cards. are assigned to COM1. 2. Clear CMOS. 122 Chapter 5 System diagnostics and troubleshooting ENWW