Computer Setup (F10) Utility menu, Save Changes, F10=YES, Ignore Changes - memory upgrade

Page 35 highlights

4. Use the arrow (left and right) keys to select the appropriate heading. Use the arrow (up and down) keys to select the option you want, and press Enter. 5. To apply and save changes, select File>Save Changes and then select F10=YES. ● If you have made changes that you do not want applied, select Ignore Changes and then select F10=YES. ● To reset to factory settings, select File>Default setup>Restore Factory Settings as Default. Press F10 to accept the changes. Select Apply Defaults and Exit. This option restores the original factory system defaults. CAUTION: Do not power off the workstation while the ROM is saving your Computer Setup (F10) Utility changes because the Complementary Metal-Oxide Semiconductor (CMOS) could become corrupted. After you exit the F10 Setup screen, it is safe to disconnect power from the workstation. Computer Setup (F10) Utility menu NOTE: The following content is subject to change with new BIOS releases, so your menu might be different than shown. Table 3-1 Computer Setup (F10) Utility menu descriptions Heading Option Description File System Lists: Information ● Product Name ● SKU Number ● Processor Type/Speed/Stepping ● Cache Size (L1/L2) ● Installed Memory Size ● Integrated MAC ● System BIOS ● Chassis Serial Number ● Asset Tracking Number About Displays copyright information. Set Time and Date Enables you to set system time and date. Flash System ROM CD-ROM - Enables you to upgrade the BIOS from a ROM image on CD. NOTE: Optical drives must be in Legacy or Native mode. USB - Enables you to upgrade the BIOS from a ROM image on a USB drive or memory stick. Replicated Setup Save to Removable Media Saves the system configuration, including CMOS, in the QSETUP.TXT file. This file can be saved to a formatted, blank 1.44-MB diskette or to a USB-connected storage device. Restore from Removable Media Restores system configuration from a diskette. Default Setup Save Current Settings as Default Saves the current settings as default settings for the next operation. ENWW Computer Setup (F10) Utility 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154

4.
Use the arrow (left and right) keys to select the appropriate heading. Use the arrow (up and down)
keys to select the option you want, and press
Enter
.
5.
To apply and save changes, select
File
>
Save Changes
and then select
F10=YES
.
If you have made changes that you do not want applied, select
Ignore Changes
and then
select
F10=YES
.
To reset to factory settings, select
File>Default setup>Restore Factory Settings as
Default
. Press
F10
to accept the changes. Select
Apply Defaults and Exit
. This option
restores the original factory system defaults.
CAUTION:
Do not power off the workstation while the ROM is saving your Computer Setup (F10)
Utility changes because the Complementary Metal-Oxide Semiconductor (CMOS) could become
corrupted. After you exit the F10 Setup screen, it is safe to disconnect power from the workstation.
Computer Setup (F10) Utility menu
NOTE:
The following content is subject to change with new BIOS releases, so your menu might be
different than shown.
Table 3-1
Computer Setup (F10) Utility menu descriptions
Heading
Option
Description
File
System
Information
Lists:
Product Name
SKU Number
Processor Type/Speed/Stepping
Cache Size (L1/L2)
Installed Memory Size
Integrated MAC
System BIOS
Chassis Serial Number
Asset Tracking Number
About
Displays copyright information.
Set Time and
Date
Enables you to set system time and date.
Flash System
ROM
CD-ROM – Enables you to upgrade the BIOS from a ROM image on CD.
NOTE:
Optical drives must be in Legacy or Native mode.
USB – Enables you to upgrade the BIOS from a ROM image on a USB drive or memory stick.
Replicated
Setup
Save to Removable Media
Saves the system configuration, including CMOS, in the QSETUP.TXT file. This file can be saved
to a formatted, blank 1.44-MB diskette or to a USB-connected storage device.
Restore from Removable Media
Restores system configuration from a diskette.
Default Setup
Save Current Settings as Default
Saves the current settings as default settings for the next operation.