August 3, 2006 Full-size keyboard integration tray Figure 71. Removing the 4820 SurePoint Solution display cable and covers a. Refer to Figure 71. Remove the 4820 filler panels in the following order ( E , F , D ). Note: When taking off filler panel F , notice that the tabs are located on the outside of the mounting bracket B . The tabs hold filler panel D in place. b. Disconnect the 4820 display cable A from the 4820 connector located on the back of the display, and from the rear connector panel on the SurePOS 500 Models 5x3 and 544/564. Remove cable. c. Remove the 4820 by removing the four screws G from the display mounting bracket B . Carefully place the 4820 display on a smooth, clean surface. Chapter 4. Removing and replacing FRUs for the SurePOS 500 Models 5x3 and 544/564 95