August 3, 2006 Common cash drawer FRUs 1. Insert the blank lock-insert handle into the blank keylock cylinder (see Figure 93 on page 116). 2. Using the blank insert handle, turn the locking screw counterclockwise until the insert can be removed from the cylinder. 3. When replacing the blank lock insert, the lug on one end of the insert must be aligned with the slot in the bottom of the lock cylinder. Hold the blank lock insert so that the lug is aligned with the slot. 4. Push the blank lock insert into the empty lock cylinder until it is flush with the top of the lock cylinder. 5. Use the blank lock-insert handle to turn the locking screw clockwise until it reaches the bottom of the hole. Do not overtighten. To replace the blank lock insert, reverse this procedure. Chapter 4. Removing and replacing FRUs for the SurePOS 500 Models 5x3 and 544/564 117