Yamaha M7CL M7cl V1 Owner's Manual - Page 129

Using user-defined keys to recall, Press the USER DEFINED KEYS tab

Page 129 highlights

Using scene memories Using user-defined keys to recall You can use the user-defined keys to directly recall a selected scene with a single keystroke, or to step through the scenes. To do this, you must first assign a scene recall operation to a user-defined key. The following recall operations can be assigned to a user-defined key. • INC RECALL ...........Immediately recalls the scene of the number that follows the currently loaded scene. • DEC RECALL ...........Immediately recalls the scene of the number that precedes the currently loaded scene. HINT • If no scene is stored in the number that precedes or follows the currently loaded scene, the closest scene number in which a scene is stored will be recalled. • DIRECT RECALL Directly recalls the scene number that you assigned to the user-defined key. When you press a user-defined key to which this function is assigned, the assigned scene will be recalled immediately. To assign one of these functions to a user-defined key so that a scene can be recalled in a single keystroke, proceed as follows. 1 In the function access area, press the SETUP button to access the SETUP screen. 3 Press the USER DEFINED KEYS tab to select the USER DEFINED KEYS page. The USER DEFINED KEYS page lets you assign functions to user defined keys [1]-[12]. User defined keys popup buttons 4 Press the popup button for the user-defined key to which you want to assign a function. The USER DEFINED KEY SETUP popup window will appear. 12 Scene memory 2 In the upper left of the screen, press the USER SETUP button to access the USER SETUP popup window. This window includes several pages, which you can switch between using the tabs located at the bottom of the window. 5 In the FUNCTION row, select "SCENE." Proceed as follows, depending on the function you want to assign. ● To assign INC RECALL or DEC RECALL Choose "INC RECALL" or "DEC RECALL" in the PARAMETER 1 column. ● To assign DIRECT RECALL Choose "DIRECT RECALL" in the PARAMETER 1 column, and choose "SCENE #xxx" (xxx is the scene number) in the PARAMETER 2 column. 6 When you've finished making settings, press the OK button to close the popup window. If desired, assign scene-recall functions to other userdefined keys in the same way. 7 Press the user-defined key to which you assigned a recall function. The corresponding scene will be recalled. M7CL Owner's Manual 129

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282

Using scene memories
129
M7CL
Owner’s Manual
Scene memory
12
You can use the user-defined keys to directly recall a
selected scene with a single keystroke, or to step through
the scenes.
To do this, you must first assign a scene recall operation to
a user-defined key. The following recall operations can be
assigned to a user-defined key.
INC RECALL
...........
Immediately recalls the scene of the
number that follows the currently loaded
scene.
DEC RECALL
...........
Immediately recalls the scene of the
number that precedes the currently
loaded scene.
DIRECT RECALL
.
...........
Directly recalls the scene number that
you assigned to the user-defined key.
When you press a user-defined key to
which this function is assigned, the
assigned scene will be recalled immedi-
ately.
To assign one of these functions to a user-defined key so
that a scene can be recalled in a single keystroke, proceed
as follows.
1
In the function access area, press the
SETUP button to access the SETUP screen.
2
In the upper left of the screen, press the
USER SETUP button to access the USER
SETUP popup window.
This window includes several pages, which you can
switch between using the tabs located at the bottom of
the window.
3
Press the USER DEFINED KEYS tab to
select the USER DEFINED KEYS page.
The USER DEFINED KEYS page lets you assign
functions to user defined keys [1]–[12].
4
Press the popup button for the user-defined
key to which you want to assign a function.
The USER DEFINED KEY SETUP popup window
will appear.
5
In the FUNCTION row, select “SCENE.”
Proceed as follows, depending on the function you
want to assign.
To assign INC RECALL or DEC RECALL
Choose “INC RECALL” or “DEC RECALL” in the
PARAMETER 1 column.
To assign DIRECT RECALL
Choose “DIRECT RECALL” in the PARAMETER
1 column, and choose “SCENE #xxx” (xxx is the
scene number) in the PARAMETER 2 column.
6
When you’ve finished making settings,
press the OK button to close the popup
window.
If desired, assign scene-recall functions to other user-
defined keys in the same way.
7
Press the user-defined key to which you
assigned a recall function.
The corresponding scene will be recalled.
Using user-defined keys to recall
If no scene is stored in the number that precedes or follows
the currently loaded scene, the closest scene number in
which a scene is stored will be recalled.
HINT
User defined keys
popup buttons