Yamaha M7CL M7cl V1 Owner's Manual - Page 136

Using the Recall Safe function

Page 136 highlights

Using the Recall Safe function Using the Recall Safe function "Recall Safe" is a function that excludes only specific parameters/channels (DCA groups) from Recall operations. This differs from the Focus settings (→ p. 135) made for individual scenes in that Recall Safe settings are common to all scenes. 1 In the function access area, press the CH JOB button to access the CH JOB popup window. RECALL SAFE button 2 Press the RECALL SAFE button to access the RECALL SAFE MODE popup window. In this popup window you can make settings for the Recall Safe function. The window contains the following items. D SAFE PARAMETER SELECT field Here you can switch Recall Safe on/off for the desired channels or DCA groups, and choose the parameters that will be excluded from Recall operations. The channel or DCA group you selected by pressing its [SEL] key will be shown in this field as the target of your operations. If you press any of the [SEL] keys of the DCA groups, the parameters for DCA groups 1-8 will be shown simultaneously. E APPLY TO ALL INPUT button / APPLY TO ALL OUTPUT button If these buttons are on when you operate the SAFE PARAMETER SELECT buttons, the changes will apply to all input (or output) channels. This is convenient when you want to make settings for all channels together. HINT • The RECALL SAFE MODE popup window can also be accessed from the SELECTED CHANNEL VIEW screen's RECALL SAFE field (→ p. 85). 1 2 3 To select the channel or DCA group whose Recall Safe settings you want to edit, press the corresponding [SEL] key. The corresponding channel or DCA group will be enclosed by a white frame in the CH RECALL SAFE 3 field. (However, this white frame does not mean that the Recall Safe setting is now enabled.) The selected channel or DCA groups 1-8 will be recalled to the SAFE PARAMETER SELECT field. 4 5 1 CH RECALL SAFE field The channels and DCA groups for which Recall Safe is turned on are highlighted in this field. If you turn on the SET BY SEL button, you can turn on Recall Safe for a channel or DCA group simply by pressing the [SEL] key of that channel or DCA group. B CLEAR ALL button This clears all Recall Safe settings for the channels or DCA groups that are highlighted in the CH RECALL SAFE field. C GLOBAL RECALL SAFE field Press the buttons in this field to select the global parameters (i.e., parameters that apply to the entire mix, rather than to specific channels) that will be set to Recall Safe. HINT • If the CH RECALL SAFE field's SET BY SEL button is on, Recall Safe will be enabled when you press the [SEL] key, and the corresponding channel or DCA group will be highlighted in the CH RECALL SAFE field. You can select parameters as described in step 4 even after turning Recall Safe on. 4 If you want to enable Recall Safe for specific parameters of the selected channel or DCA group, make the following settings in the SAFE PARAMETER SELECT field. NOTE • Simply selecting a parameter in step 4 does not enable Recall Safe. To turn Recall Safe on/off, you must also perform the operation of step 5. HINT • While the APPLY TO ALL INPUT button (or the APPLY TO ALL OUTPUT button) is on, operations in the SAFE PARAMETER SELECT field will apply to all input channels (or output channels). 136 M7CL Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282

M7CL
Owner’s Manual
Using the Recall Safe function
136
“Recall Safe” is a function that excludes only specific parameters/channels (DCA groups) from
Recall operations. This differs from the Focus settings (
p. 135) made for individual scenes in
that Recall Safe settings are common to all scenes.
1
In the function access area, press the CH
JOB button to access the CH JOB popup
window.
2
Press the RECALL SAFE button to access
the RECALL SAFE MODE popup window.
In this popup window you can make settings for the
Recall Safe function. The window contains the follow-
ing items.
1
CH RECALL SAFE field
The channels and DCA groups for which Recall Safe
is turned on are highlighted in this field. If you turn on
the SET BY SEL button, you can turn on Recall Safe
for a channel or DCA group simply by pressing the
[SEL] key of that channel or DCA group.
B
CLEAR ALL button
This clears all Recall Safe settings for the channels or
DCA groups that are highlighted in the CH RECALL
SAFE field.
C
GLOBAL RECALL SAFE field
Press the buttons in this field to select the global
parameters (i.e., parameters that apply to the entire
mix, rather than to specific channels) that will be set to
Recall Safe.
D
SAFE PARAMETER SELECT field
Here you can switch Recall Safe on/off for the desired
channels or DCA groups, and choose the parameters
that will be excluded from Recall operations. The
channel or DCA group you selected by pressing its
[SEL] key will be shown in this field as the target of
your operations. If you press any of the [SEL] keys of
the DCA groups, the parameters for DCA groups 1–8
will be shown simultaneously.
E
APPLY TO ALL INPUT button / APPLY TO
ALL OUTPUT button
If these buttons are on when you operate the SAFE
PARAMETER SELECT buttons, the changes will
apply to all input (or output) channels. This is conve-
nient when you want to make settings for all channels
together.
3
To select the channel or DCA group whose
Recall Safe settings you want to edit, press
the corresponding [SEL] key.
The corresponding channel or DCA group will be
enclosed by a white frame in the CH RECALL SAFE
field. (However, this white frame does not mean that
the Recall Safe setting is now enabled.) The selected
channel or DCA groups 1–8 will be recalled to the
SAFE PARAMETER SELECT field.
4
If you want to enable Recall Safe for spe-
cific parameters of the selected channel or
DCA group, make the following settings in
the SAFE PARAMETER SELECT field.
Using the Recall Safe function
RECALL SAFE button
1
2
5
4
3
The RECALL SAFE MODE popup window can also be
accessed from the SELECTED CHANNEL VIEW screen’s
RECALL SAFE field (
p. 85).
HINT
If the CH RECALL SAFE field’s SET BY SEL button is on,
Recall Safe will be enabled when you press the [SEL] key,
and the corresponding channel or DCA group will be high-
lighted in the CH RECALL SAFE field. You can select param-
eters as described in step 4 even after turning Recall Safe on.
HINT
Simply selecting a parameter in step 4 does not enable Recall
Safe. To turn Recall Safe on/off, you must also perform the
operation of step 5.
NOTE
While the APPLY TO ALL INPUT button (or the APPLY TO
ALL OUTPUT button) is on, operations in the SAFE PARAM-
ETER SELECT field will apply to all input channels (or output
channels).
HINT