Chapter 3 Main Panel Window • [Scene Change] GPI input can be used to recall a specified scene. [Parameter] specifies the number of the scene to be recalled. [Min] and [Max] are not available. [Terminal] determines how the GPI input voltage will affect the specified parameter. The scene specified by [Parameter] will be recalled each time the voltage applied to GPI IN rises from below to above the median voltage.* Max. voltage applied to GPI IN Median voltage Min. voltage applied to GPI IN Trigger The scene specified by [Parameter] will be recalled each time the voltage applied to GPI IN drops from above to below the median voltage.* Max. voltage applied to GPI IN Trigger Median voltage Min. voltage applied to GPI IN Same as . Same as . • [Scene Increment] GPI input can be used to increment the scene number. [Parameter], [Min], and [Max] are not available. [Terminal] determines how the GPI input voltage will affect the specified parameter. The scene number will be incremented each time the voltage applied to GPI IN rises from below to above the median voltage.* Max. voltage applied to GPI IN Median voltage Min. voltage applied to GPI IN Trigger The scene number will be incremented each time the voltage applied to GPI IN drops from above to below the median voltage.* Max. voltage applied to GPI IN Trigger Median voltage Min. voltage applied to GPI IN Same as . Same as . 116 DME Designer Owner's Manual