Yamaha V4.0 DME Designer V4.0 Owners Manual - Page 411
Double click the component to open the component editor. Mono channel and stereo channel, components
![]() |
View all Yamaha V4.0 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 411 highlights
Chapter 6 Component Guide Double click the component to open the component editor. Mono channel and stereo channel components have the same parameters. Limiter component editor Limiter Curve Name Gain Reduction Meter Output Meter Parameter Setting Range Threshold -54 dB to ±0 dB Attack 0 to 120 ms Release 44.1 kHz: 6 ms to 46 s 48 kHz: 5 ms to 42.3 s 88.2 kHz: 3 ms to 23 s 96 kHz: 3 ms to 21.1 s KeyIn Mono SELF KEYIN Stereo L R LR BOTH KEYIN On ON/OFF Function Displays the limiter response in graph form. The horizontal axis represents input signal level and the vertical axis represents output level. Displays the amount of gain reduction. Displays the output signal level. Function Sets the threshold value. Sets the attack time. Sets the release time. The range varies according to the operating frequency. The trigger source can be selected from this menu. The currently selected source is displayed in the button. Turns the limiter ON. Output Level (dB) +20 RATIO=20:1 +10 0 Threshold = -20dB -10 -20 -30 -40 -50 -60 -70 -70 -60 -50 -40 -30 -20 -10 0 +10 +20 Input Level (dB) DME Designer Owner's Manual 411
![](/manual_guide/products/yamaha-v40-dme-designer-v40-owners-manual-50920ae/411.png)