Yamaha V4.0 DME Designer V4.0 Owners Manual - Page 404
compressors have two inputs, two outputs, and one KeyIn input.
View all Yamaha V4.0 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 404 highlights
Chapter 6 Component Guide Parameter KeyIn On Setting Range Mono SELF KEYIN Stereo L R LR BOTH KEYIN ON/OFF Function Selects the trigger source from a menu. The currently selected trigger source is displayed on the button. Turns the compander ON. Output Level (dB) Ratio=4:1 +20 Width=25 +10 0 -10 -20 -30 -40 -50 Threshold = -25dB -60 -70 -70 -60 -50 -40 -30 -20 -10 0 +10 +20 Input Level (dB) Compressor Compresses signals that exceed a threshold. Narrows the dynamic range of the signal, making it easier to mix or record signals with a wide dynamic range such as vocals or piano music. Both mono channel and stereo channel compressors are provided. Mono channel compressors have one input, one output, and one KeyIn input. Stereo channel compressors have two inputs, two outputs, and one KeyIn input. Double-click a component to open the component editor for it. The parameters are the same for mono channel and stereo channel components. Compressor component editor Compressor Curve Name Gain Reduction Meter Output Meter 404 DME Designer Owner's Manual Function Displays results graphically. The horizontal axis is the input signal level, and the vertical axis is the output level. Displays the gain reduction attenuation. Displays the output signal level.