Dell PowerEdge XL 5133-4 Dell PowerEdge FTOS Command Line Reference Guide for
Dell PowerEdge XL 5133-4 Manual
View all Dell PowerEdge XL 5133-4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerEdge XL 5133-4 manual content summary:
- Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 1
Dell PowerEdge FTOS Command Line Reference Guide for the M I/O Aggregator Publication Date: March 2013 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 2
to hardware or loss of data and tells you how to avoid the problem. Dell Inc. is strictly forbidden. Trademarks used in this text: Dell(TM), the Dell logo, Dell Boomi(TM), Dell Precision(TM) , OptiPlex(TM), Latitude(TM), PowerEdge Microsoft(R), Windows(R), Windows Server(R), Internet Explorer(R), MS- - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 3
1 About this Guide 5 Objectives 5 Audience 5 Conventions 5 Related Documents 6 2 Before You Start 7 Default Settings 7 Other Auto-Configured Settings 7 DCB Support 8 FCoE Connectivity 8 iSCSI Operation 8 Link Aggregation 9 Link Tracking 9 VLANs 9 Uplink LAG 9 Server-Facing LAGs 10 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 4
www.dell.com | support.dell.com 5 Control and Monitoring 39 Commands 39 Important Points to Remember 62 6 u-Boot 79 Overview 79 Commands 79 7 Data Center Bridging 89 Overview 89 DCB Command 89 PFC Commands 89 ETS Commands 89 DCBX Commands 89 8 Dynamic Host Configuration Protocol (DHCP - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 5
193 Monitoring Commands 193 Important Points to Remember 193 18 Quality of Service (QoS 199 Overview 199 Policy-Based QoS Commands 199 19 Security 201 Commands 201 Authentication and Password Commands 201 SSH Server and SCP Commands 201 20 Simple Network Management Protocol (SNMP) and - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 6
www.dell.com | support.dell.com Storm Control Commands 227 23 System Time 229 Overview 229 Time Commands 229 24 Uplink Failure Detection (UFD 237 Overview 237 UFD Commands 237 25 Debugging and Diagnostics 245 Offline Diagnostic Commands 245 Important Points to Remember 245 Hardware - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 7
1 About this Guide This book provides information about the Dell Force10 operating software (FTOS) command line interface (CLI) on the Dell PowerEdge M I/O Aggregator. It includes some information about the protocols and features found in FTOS and on the Dell Force10 systems supported by FTOS. This - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 8
www.dell.com | support.dell.com x | y Keywords and parameters separated by bar require you to system, refer to the following documents: • Dell PowerEdge Configuration Guide for the M I/O Aggregator • Dell PowerEdge M I/O Aggregator Getting Started Guide • Release Notes for the M I/O Aggregator - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 9
to access the CMC to configure an Aggregator, refer to the Dell PowerEdge M1000e Enclosure Hardware Owner's Manual or Dell Chassis Management Controller (CMC) User's Guide on the Dell Support website at http://support.dell.com/support/edocs/systems/pem/en/index.htm. Other Auto-Configured Settings - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 10
www.dell.com | support.dell.com • Fibre Channel over Ethernet (FCoE) connectivity • FCoE Enabled on all ports. • Link tracking: Enables server-facing links to be brought up only if the uplink port-channel (LAG 128) is up. • Stacking: Stacking is supported only on the 40GbE ports on the base module - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 11
-configured as part of link aggregation groups if the corresponding server is configured for LACP-based NIC teaming. Static LAGs are not supported. Tip: The recommended LACP timeout is long-timeout mode. Link Tracking By default, all server-facing ports are tracked by the operational status of the - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 12
dell.com | support.dell.com The untagged VLAN used for the uplink LAG is always the default VLAN. Server-Facing LAGs The tagged VLAN membership of a server-facing LAG is automatically configured based on the server-facing ports that are members of the LAG. The untagged VLAN of a server had manually - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 13
to see that an Aggregator is running the latest FTOS version by entering the show version command. To download an FTOS version, go to http:// support.dell.com. Refer to the appropriate chapter for detailed information on how to configure specific software settings. Before You Start | 11 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 14
12 | Before You Start www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 15
3 CLI Basics This chapter describes the command structure and command modes. The Dell Force10 operating software (FTOS) commands are in a text-based interface that allows you to use launch commands, change the command modes, and configure interfaces and protocols. This chapter - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 16
www.dell.com | support.dell.com Multiple Configuration Users When a user enters CONFIGURATION mode and another user(s) is already in that configuration mode, FTOS generates an alert warning message similar - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 17
Obtaining Help As soon as you are in a command mode, there are several ways to access help. • To obtain a list of keywords at any command mode, do the following: - Enter a ? at the prompt or after a keyword. There must always be a space before the ?. • To obtain a list of keywords with a brief - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 18
www.dell.com | support.dell.com Table 3-2. Short-cut Keys and their Actions Key Combination CNTL-X CNTL-Z Esc B Esc F Esc D Action Deletes the line. Comes back to EXEC mode from - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 19
no {boot | default | enable | ftp-server | hardware | hostname | ip | line | logging | monitor | service | io-aggregator broadcast storm-control | snmp-server | username} Defaults None Command Modes CONFIGURATION Command History Version 8.3.17.0 Supported on M I/O Aggregator Filtering show - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 20
www.dell.com | support.dell.com Displaying All Output To display the output all at once (not one screen at a time), use the no-more command after the pipe. This - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 21
From this mode, you can enter INTERFACE mode using the interface command. INTERFACE Mode Use INTERFACE mode to configure interfaces or IP services on those interfaces. An interface can be physical (for example, a TenGigabit Ethernet port) or virtual (for example, the Null interface). To enter - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 22
www.dell.com | support.dell.com PROTOCOL LLDP Mode While in CONFIGURATION mode, use the protocol lldp command to enter PROTOCOL LLDP mode. Use this mode to configure the LLDP - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 23
found in the Dell Force10 operating software (FTOS). Basic File Management Commands The commands included in this chapter are: • boot system gateway • boot system stack-unit • cd • copy • copy running-config startup-config • delete • dir • format flash • logging coredump server - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 24
www.dell.com | support.dell.com boot system gateway Specify the IP address of the default next-hop gateway for the management subnet. Syntax boot system gateway ip-address Parameters - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 25
supported. For a list of approved USB vendors, refer to the FTOS Release Notes. When copying a file to a remote location (for example, using Secure of the startup configuration. FTOS supports copying the running-configuration to a TFTP server or to an FTP server: copy running-config tftp: copy - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 26
www.dell.com | support.dell.com Example Figure 4-1. copy running-config scp: Command Example FTOS#copy running-config scp: Address or name of remote host []: 10.10.10.1 Port number of the server [22]: 99 Destination file name [startup-config]: old_running User name to login remote host: sburgess - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 27
that FTOS does not require user input for each file prior to deletion. Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator dir Displays the files in a file system. The default is the current directory. Syntax dir [filename | directory name:] Parameters - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 28
www.dell.com | support.dell.com Example Figure 4-3. dir for the Internal Flash Command Example FTOS#dir Directory usbflash:} Default flash memory Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage Information You must include the colon (:) when - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 29
Type 7 hashing algorithm. Enter a password to access the target server. Defaults Crash kernel files are uploaded to flash by default. Command Modes CONFIGURATION Command History Usage Information Related Commands Version 8.3.17.0 Supported on M I/O Aggregator The Kernel core dump can be large - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 30
www.dell.com | support.dell.com pwd Displays the current working directory. Syntax pwd Command Modes Command History Example EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 4-4. pwd Command Example FTOS#pwd flash: FTOS# Related Commands cd Changes the working directory. - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 31
Command History Version 8.3.17.1 Supported on M I/O Aggregator Usage Restoring factory defaults deletes the existing startup configuration and all persistent settings Information (stacking, fanout, etc.). When restoring all units in a stack, - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 32
www.dell.com | support.dell.com Figure 4-7. restore factory-defaults (NvRAM only, all units in a stack) Command Example FTOS#restore factory-defaults stack-unit all nvram * Warning - Restoring factory defaults - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 33
For a file on the external Flash, enter usbflash:// followed by the filename. Command Modes EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 4-10. show file Command Example (Partial) FTOS#show file flash://startup-config ! Version E8-3-17-38 boot system - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 34
dell.com | support.dell.com show file-systems Displays information about the file systems on the system. Syntax show file-systems Command Modes EXEC Privilege Command History Example Version 8.3.17.0 Supported Displays the release and software image version information of the image file specified - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 35
/filepath • For a file on a TFTP server, enter tftp://hostip/filepath • For a file on the external Flash, enter usbflash:// followed by the filename. Defaults none Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage Information Note: A filepath - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 36
www.dell.com | support.dell.com status • management-route for the current Management port forwarding system: A: boot system gateway 10.11.209.62 ! redundancy auto-synchronize full ! service timestamps log datetime ! hostname FTOS ... Example Figure 4-14. show running-config Command Example - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 37
Example Figure 4-15. show version Command Example FTOS#show version Dell Force10 Real Time Operating System Software Dell Force10 Operating System Version: 1.0 Dell Force10 Application Software Version: E8-3-17-38 Copyright (c) 1999-2012 by Dell Inc. All Rights Reserved. Build Time: Thu Jul 19 05:59 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 38
www.dell.com | support.dell.com all booted ftp tftp flash usbflash A B Enter this keyword to B Defaults none Command Modes Command History Usage Information Example EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator You must reload FTOS after executing this command. Figure 4-16. - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 39
Enter this keyword to upgrade the bootflash partition B Defaults Command Modes Command History Usage Information Example none EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator You must reload FTOS after executing this command. Use the command upgrade system stack-unit to copy FTOS from - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 40
38 | File Management www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 41
ftp-server enable ftp-server topdir ftp-server username hostname ip telnet server enable ip telnet source-interface line ping reload service timestamps ipc flow-control show processes memory show server-interfaces show system show revision show tech-support show uplink brief show util-threshold cpu - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 42
www.dell.com | support.dell.com clear alarms Clear the alarms on the system. Syntax clear alarms Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage This command clears alarms that are no longer active. If an alarm situation is still active, it is - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 43
traffic statistics. Dell Force10 recommends disabling debugging (no debug cpu-traffic-stats) after troubleshooting is complete. directly with a technical support representative to troubleshoot a problem. Do not use this command unless a technical support representative instructs you to do so. - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 44
www.dell.com | support.dell.com disable Return to EXEC mode. Syntax disable [level] Parameters level (OPTIONAL) Enter a number for a privilege level of the FTOS. Range: 0 to 15. Default: 1 Defaults 1 Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 45
Related Commands end Returns to EXEC Privilege command mode. ftp-server enable Enable the FTP server functions on the system. Syntax ftp-server enable Defaults Disabled. Command Modes CONFIGURATION Command History Version 8.3.17.0 Supported on M I/O Aggregator Control and Monitoring | 43 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 46
default directory. Command Modes CONFIGURATION Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator After you enable FTP server functions with the ftp-server enable command, Dell Force10 recommends specifying a top-level directory path. Without a top-level directory - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 47
M I/O Aggregator hostname Set the host name of the system. Syntax hostname name Parameters name Enter a text string, up to 32 characters long. Defaults FTOS Command Modes CONFIGURATION Command History Version 8.3.17.0 Supported on M I/O Aggregator ip telnet server enable Enable the Telnet - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 48
www.dell.com | support.dell.com ip telnet source-interface Set an interface's IP address as followed by a number from 0 to 9 to configure a virtual terminal line for Telnet sessions. The system supports 10 Telnet sessions. (OPTIONAL) Enter a number from 1 to 9 as the last virtual terminal line to - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 49
device by sending echo requests and waiting for replies. Syntax ping [host | ip-address] [count {number | continuous}] [datagram-size] enter the keyword vlan followed by a number from 1 to 4094. Enter the type of service required. Range: 0-255 Default: 0 Enter Y or N for the don't fragment bit - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 50
www.dell.com | support.dell.com sweep-interval ointerface Enter the incremental value for Reboot FTOS. Syntax reload Command Modes EXEC Privilege Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator If there is a change in the configuration, FTOS prompts you - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 51
reboot. Defaults Not configured. Command Modes CONFIGURATION Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage If you do not specify parameters and enter service timestamps, it appears as service timestamps Information debug uptime in the running-configuration. Use the show - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 52
www.dell.com | support.dell.com Example Figure 5-4. show alarms Command Example FTOS# show alarms -- Defaults Command Mode None. EXEC EXEC Privilege Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator One trace log message is generated for each command. No - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 53
- Repeated 1 time. [7/19 14:44:41]: CMD-(CLI):[snmp-server community public ro]by default from console [7/19 14:44:41]: 209.4]by default from console [7/19 14:44:43]: CMD-(CLI):[service timestamps log datetime]by default from console [7/19 14:44:43]: Supported on M I/O Aggregator Control and - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 54
www.dell.com | support.dell.com Example Figure 5-6. show configuration lock Command Output FTOS# show other users every time the user on the listed VTY line enters CONFIGURATION mode. When set to manual, the user on the listed VTY line must explicitly set the lock each time before entering - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 55
debugging Displays a list of all enabled debugging processes. Syntax show debugging Command Mode EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 5-8. show debugging Command Example FTOS#show debug Generic IP: (Access List: test) IP packet debugging is - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 56
www.dell.com | support.dell.com Command History Version 8.3.17.0 Supported on M I/O Aggregator show environment Displays the system Command Modes EXEC EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 5-9. show environment all Command Example - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 57
the switch type, components (including media), FTOS version including hardware identification numbers and configured protocols. Syntax show inventory {[media . Defaults none Command Modes EXEC Command History Usage Version 8.3.17.0 Supported on M I/O Aggregator If there are no fibre ports in the - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 58
.dell.com | support.dell.com Example 1 Figure 5-12. show inventory for M I/O Aggregator Command Example FTOS#show inventory System Type System Mode Software NVH81X-00000-000-0000 01 N/A N/A * - Management Unit Software Protocol Configured DCBX Fip Snooping IGMP iSCSI LLDP SNMP FTOS# Example - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 59
ID of the stack member to display memory information on the designated stack member. Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage The output for the show memory command displays the memory usage of LP part (sysdlp) of the Information - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 60
www.dell.com | support.dell.com ipc memory (OPTIONAL) Enter the keyword ipc to display inter-process communication statistics. (OPTIONAL) Enter the keyword memory to display memory statistics. See Example 4. Command Modes EXEC EXEC Privilege Command History Example 1 Version 8.3.17.0 Supported - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 61
Example 3 Figure 5-18. show processes cpu stack-unit Command Example FTOS#show process cpu stack-unit 1 PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 0x763a3000 17981680 1798168 10000 3.00% 2.67% 2.67% 0 KP 0x762ba000 0 0 0 0.00% 0.00% 0.00% 0 debugagt 0x762d9000 0 0 0 0.00% - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 62
www.dell.com | support.dell.com Example 4 Figure 5-19. show processes memory Command Example FTOS#show process memory Memory 9445376 192512 7585792 192512 14774272 192512 12636160 Related Commands show diag show hardware system-flow Displays the data plane or management plane input and output - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 63
Command History Example 1 Version 8.3.17.0 Supported on M I/O Aggregator Figure 5-21. 25 0 25 25 47 60 60 3 60 60 Table 5-1 lists the definitions of the fields shown in Figure 5-21. Table 5-1. Description of the show Source Service Identifier Destination Service Identifier Current number of - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 64
www.dell.com | support.dell.com Table 5-1. Description of the show processes ipc flow-control cp (SWP) provides flow control-based reliable communication between the Information sending and receiving software tasks. Important Points to Remember • A sending task enqueues messages into the SWP - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 65
Usage Information Example The output for the show process memory command displays the memory usage statistics running on CP part (sysd) of the system. The Sysd is an aggregate task that handles all the tasks running on M I/O Aggregator's CP. The output of show memory and this command will differ - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 66
www.dell.com | support.dell.com Table 5-2 defines the fields that appear in the show processes memory output. use show server-interfaces Displays server port information. Syntax show server-interfaces {brief | detail} Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 67
down up down down up Description Example Figure 5-25. show server-interfaces detail Command Example FTOS#show server-interfaces detail show server ports detail TenGigabitEthernet 0/1 is up, line protocol is down(error-disabled[UFD]) Hardware is DellForce10Eth, address is 00:1e:c9:f1:00:99 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 68
www.dell.com | support.dell.com show system Displays the current status of all stack members stack member. Range: 0 to 5. Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage Figure 5-26 shows the output from the show system brief command. - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 69
- 34-port GE/TE (XL) Master priority : 0 Hardware Rev : 01 Num Ports : 56 Up Time : 4 DELL Mfg Date : Serial Number : 00000000000000 Part Number : NVH81X01 Piece Part ID : 00-NVH81X-00000-000-0000 PPID Revision : 01 Service Supported on M I/O Aggregator Control and Monitoring | - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 70
-- Stack unit 1 -- IOM SYSTEM CPLD : 1 FTOS# show tech-support Displays a collection of data from other show commands, necessary for Dell Force10 technical support to perform troubleshooting on M I/O Aggregators. Syntax show tech-support [stack-unit unit-id | page] Parameters stack-unit page - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 71
of a pattern grep Show only text that matches a pattern no-more Don't paginate output save Save output to a file FTOS#show tech-support stack-unit 1 | save ? flash: Save to local file system (flash://filename (max 20 chars) ) usbflash: Save to local file system (usbflash://filename - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 72
dell.com | support.dell.com Figure 5-30. show tech-support Command Example (Partial) FTOS#show tech-support stack-unit 1 show version Dell Force10 Real Time Operating System Software Dell Force10 Operating System Version: 1.0 Dell Force10 Application Software full ! service timestamps log - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 73
Enter the keyword detail to display uplink port information with description. Command Modes EXEC Privilege Command History Example 1 Version 8.3.17.0 Supported on M I/O Aggregator Figure 5-31. show uplink brief Command Example FTOS#show uplink brief show uplink brief Interface OK Status - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 74
www.dell.com | support.dell.com Example 2 Figure 5-32. show uplink detail Command Example FTOS#show uplink detail show uplink detail TenGigabitEthernet 0/41 is up, line protocol is down Hardware is DellForce10Eth, address is 00:1e:c9:f1:00:99 Current address is 00:1e:c9:f1:00:99 Port is not - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 75
I/O Aggregator telnet Connect through Telnet to a server. The Telnet client and server in FTOS supports IPv4 connections. You can establish a Telnet session directly to the router, or a connection can be initiated from the router. Syntax telnet {host | ip-address} [/source-interface] Parameters - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 76
www.dell.com | support.dell.com telnet-peer-stack-unit Open a telnet connection to the peer stack-unit. Syntax telnet-peer-stack-unit Defaults Not Configured Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator terminal length Configure the number - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 77
. Defaults Disabled. Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator traceroute View the packet path to a specific device. Syntax traceroute {host | ip-address} Parameters host ip-address Enter the name of device. Enter the IP address of - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 78
www.dell.com | support.dell.com Example Figure 5-33. traceroute (IPv4) Command Example FTOS#traceroute www.force10networks.com Translating "www.force10networks.com"...domain server (10.11.0.1) [OK] Type Ctrl-C to abort. Tracing the route to www.force10networks.com (10.11.84.18), 30 hops max, - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 79
Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator The write memory command saves the running-configuration to the file labeled startup-configuration. When using a LOCAL CONFIG FILE other than the startup- - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 80
78 | Control and Monitoring www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 81
6 u-Boot Overview All commands in this chapter are in u-Boot mode. These commands are supported on the Dell Force10 Aggregator only. To access this mode, hit any key when the following line appears on the console during a system boot: Hit any key to - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 82
www.dell.com | support.dell.com • show interface management port config • syntax help Note: You cannot use partition. Syntax boot selection [a | b] Command Modes uBoot Command History Version 8.3.17.0 Supported on M I/O Aggregator boot show net config retries Show the number of retries for - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 83
network boot configuration failure. Syntax boot write net config retries Command Modes uBoot Command History Example Version 8.3.17.0 u Supported on M I/O Aggregator Figure 6-2. boot write net config retries Command Example BOOT_USER # boot write net config retries 2 Updated number of - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 84
Displays the help menu. Syntax help Command Modes uBoot Command History Version 8.3.17.0 u Supported on M I/O Aggregator Example Figure 6-3. help Command Example BOOT_USER # help ***** Dell Force10 Boot Interface Help Information ***** Current access level: USER LEVEL Use "syntax help" for - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 85
no default gateway Clear the default gateway IP address. Syntax no default-gateway Command Modes uBoot Command History Version 8.3.17.0 u Supported on M I/O Aggregator no interface management ethernet ip address Clear the management port IP address and mask. Syntax no interface management - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 86
www.dell.com | support.dell.com show boot blc Show the boot loop counter value. Syntax show boot blc Command Modes uBoot Command History Version 8.3.17.0 u Supported on M I/O Aggregator Example Figure 6-4. show boot blc Command Example BOOT_USER # show boot blc ? Total 1 possible command - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 87
Command History Version 8.3.17.0 Supported on M I/O Aggregator Example Figure 6-6. show bootflash Command Example BOOT_USER # show bootflash GENERAL BOOTFLASH INFO Bootflash Partition A: Dell Force10 Networks System Boot Official IOM_LP_IMG_BOOT_LOADER, BSP Release 4.0.1.0bt1 Created Tue May 1 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 88
www.dell.com | support.dell.com Example Figure 6-7. show bootvar Command Example BOOT_USER # show bootvar PRIMARY OPERATING SYSTEM BOOT PARAMETERS: boot device : tftp file name : premnath Management Etherenet IP address : 10.16.130.134/16 Server IP address : 10.16.127.35 Default - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 89
the management port boot characteristics. Syntax show interface management port config Command Modes uBoot Command History Version 8.3.17.0 u Supported on M I/O Aggregator Example Figure 6-10. show interface management port config Command Example BOOT_USER # show interface management port - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 90
88 | u-Boot www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 91
a single, robust, converged network to support multiple traffic types, including LAN, server, and storage traffic. Data center bridging (DCB) features are auto-configured in standalone mode and supported in stacking mode. The Dell Force10 operating software (FTOS) commands for data center bridging - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 92
www.dell.com | support.dell.com clear ets counters Clear ETS TLV counters. Syntax Parameters clear ets counters [tengigabitethernet slot/port] slot/port Enter the slot/port number. Defaults None Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 93
Command History Version 8.3.17.4 Version 8.3.17.0 Added auto-detect parameter. Supported on M I/O Aggregator Example 1 Figure 7-1. Disable DCB Command Example FTOS#show dcb stack-unit 0 port-set 0 stack-unit 0 port-set 0 DCB Status : Enabled PFC Port Count : - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 94
www.dell.com | support.dell.com Example 2 Figure 7-2. Enable DCB Command Example FTOS#show dcb stack-unit 0 port-set 0 reload, PFC buffers will be reserved for all pfc ports and max loss less queues supported for each stack unit. For the pfc-buffering change to take effect, please save the - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 95
%DIFFSERV-6-DCB_ENABLE_CFG_ON_RELOAD: Global DCB will be enabled on subsequent reload, PFC buffers will be reserved for all pfc ports and max loss less queues supported for each stack unit. For the pfc-buffering change to take effect, please save the config and reload the system. FTOS(conf)#end FTOS - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 96
www.dell.com | support.dell.com dcbx version Configure the DCBX version used on the interface. 802.1az (Draft 2.5). Defaults Auto Command Modes PROTOCOL LLDP Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage Information DCBX requires that you enable LLDP to advertise DCBX - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 97
Parameters unit number Enter the DCB unit number. The valid values are 0 to 5. Command Mode EXEC PRIVILEGE Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 7-4. show dcb Command Example FTOS# show dcb stack-unit 0 port-set 0 DCB Status : Enabled PFC Port Count : 56 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 98
www.dell.com | support.dell.com Example Figure 7-5. show interface dcbx detail Command Example FTOS# configuration as compatible. In auto-detection mode, a port can only operate on a DCBX version supported on the remote peer. Local DCBX Configured DCBX version configured on the port: CEE, CIN, - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 99
Operational Version DCBX version advertised in Control TLVs received from the peer device. Peer DCBX Status: DCBX Max Version Supported Highest DCBX version supported in Control TLVs received from the peer device. Peer DCBX Status: Sequence Number Sequence number transmitted in Control TLVs - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 100
www.dell.com | support.dell.com Example Figure 7-6. show interfaces ets summary Command Example FTOS#show interface tengigabitethernet 1/1 ets summary Interface TenGigabitEthernet 1/1 Max Supported TC Groups is 4 Number of Traffic Classes is 8 Admin mode is on Admin Parameters Admin is enabled - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 101
Example Figure 7-7. show interfaces ets detail Command Example FTOS#show interface tengigabitethernet 1/1 ets detail Interface TenGigabitEthernet 1/1 Max Supported TC Groups is 4 Number of Traffic Classes is 8 Admin mode is on Admin Parameters Admin is enabled TC-grp Priority# Bandwidth TSA - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 102
www.dell.com | support.dell.com Usage Information Table 7-2 lists the show interface ets summary field descriptions. Table 7-2. show interfaces ets detail Command Example Fields Field Description Interface Interface type with stack-unit and port number. Max Supported TC Group Maximum number - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 103
or enter the keyword detail for a full list of results. Command Mode EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 7-8. show interface pfc summary Command Example FTOS# show interfaces tengigabitethernet 0/49 pfc summary Interface TenGigabitEthernet - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 104
www.dell.com | support.dell.com Example Figure 7-9. show interface pfc detail Command Example FTOS# show interfaces tengigabitethernet 0/49 pfc detail Interface TenGigabitEthernet 0/49 Admin mode is on Admin is - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 105
/port pfc statistics Parameters port-type slot/port Enter the port type. Enter the slot/port number. Command Mode EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Data Center Bridging | 103 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 106
www.dell.com | support.dell.com Example Figure 7-10. show interfaces pfc statistics Command Example FTOS#show interface tengigabitethernet . Enter the port number. Command Mode EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator 104 | Data Center Bridging - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 107
. show stack-unit stack-ports ets detail Command Example FTOS#show stack-unit all stack-ports all ets details Stack unit 1 stack port all Max Supported TC Groups is 4 Number of Traffic Classes is 1 Admin mode is on Admin Parameters: Admin is enabled TC-grp Priority# Bandwidth TSA - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 108
106 | Data Center Bridging www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 109
addresses and other configuration parameters to network end-stations (hosts) based on configuration policies determined by network administrators. from a DHCP server. The following types of DHCP commands are described in this chapter: • DHCP Client Commands • Other Commands supported by DHCP Client - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 110
www.dell.com | support.dell.com ip address dhcp Acquire an IP address dynamically on an interface from the DHCP server. Syntax ip address dhcp To diable DHCP Client on an interface, Syntax debug ip dhcp client events [interface type slot/port] 108 | Dynamic Host Configuration Protocol (DHCP) - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 111
from 1 to 4094. Command Mode EXEC Privilege Default None Command History Version 8.3.17.0 Supported on M I/O Aggregator debug ip dhcp clients packets Enable the display of log messages for 1 to 4094. Command Mode EXEC Privilege Default None. Dynamic Host Configuration Protocol (DHCP) | 109 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 112
.dell.com | support.dell.com Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator When you enter the release dhcp command, although the IP address that was dynamically-acquired from a DHCP server is released from an interface, the ability to acquire a new DHCP server - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 113
Command History Version 8.3.17.0 Supported on M I/O Aggregator show ip dhcp lease Displays lease information about the dynamic IP on all DHCP client-enabled interfaces on the switch. Command History Version 8.3.17.0 Supported on M I/O Aggregator Dynamic Host Configuration Protocol (DHCP) | 111 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 114
www.dell.com | support.dell.com 112 | Dynamic Host Configuration Protocol (DHCP) - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 115
permit only authorized FCoE traffic to be transmitted between an FCoE end-device and an FCF. FIP Snooping Commands The following Dell Force10 operating software (FTOS) commands are used to configure and verify the FIP snooping feature: • clear fip-snooping statistics • debug fip-snooping • show fip - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 116
www.dell.com | support.dell.com Command History Version 8.3.17.0 Supported on M I/O Aggregator debug fip-snooping Enable the debug FIP protocol debugs Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator show fip-snooping config Displays the FIP - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 117
Enter the MAC address of the ENodes to be displayed. Command Mode Command History Example • EXEC • EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 9-2. show fip-snooping enode Command Example FTOS# show fip-snooping enode Enode MAC Enode Interface --------- d4:ae - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 118
www.dell.com | support.dell.com Example Figure 9-3. show fip-snooping fcf Command Example FTOS# show fip-snooping fcf FCF MAC FCF id of the specified VLAN to be displayed. Command Mode Command History • EXEC • EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator 116 | FIP Snooping - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 119
Example Figure 9-4. show fip-snooping sessions Command Example FTOS#show fip-snooping sessions Enode MAC Enode Intf FCF MAC FCF Intf VLAN FCoE MAC FC-ID 00:0e:1e:0c:54:a6 Te 0/14 00:05:73:f2:4f:ae Po128 100 0e:fc:00:9a:00:27 9a:00:27 20:01:00:0e:1e:0c:54:a6 00:0e:1e:06:01:5e Te 0/16 00:05:73: - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 120
www.dell.com | support.dell.com Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 9-5. CVL Number of FCF Discovery Timeouts Number of VN Port Session Timeouts Number of Session failures due to Hardware Config FTOS(conf)# :0 :0 :2 :0 :2 :16 :0 :9021 :3349 :4437 :2 :2 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 121
:0 Number of CVL :0 Number of FCF Discovery Timeouts :0 Number of VN Port Session Timeouts :0 Number of Session failures due to Hardware Config :0 Table 9-4 lists the show fip-snooping statistics command field descriptions. Table 9-4. show fip-snooping statistics Command Fields Description - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 122
www.dell.com | support.dell.com Table 9-4. show fip-snooping statistics Command Fields interface Number of Session failures due to Number of session failures due to hardware configuration that Hardware Config occurred on the interface show fip-snooping system Displays information on the - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 123
10 Internet Group Management Protocol (IGMP) IGMP Commands The Dell Force10 operating software (FTOS) supports internet group management protocol (IGMP) snooping version 2 and 3 on all Dell Force10 systems: • clear ip igmp groups • debug ip igmp • ip igmp snooping flood • show ip igmp groups • show - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 124
www.dell.com | support.dell.com clear ip igmp groups Clear entries from the group cache table. a number from 1 to 4094. Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator ip igmp snooping flood This command controls the flooding behavior of - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 125
Command Modes EXEC EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 10-1. show ip igmp snooping amount of time until the entry expires. Displays the IP address of the last host to be a member of the IGMP group. Indicates the member ports of the port - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 126
www.dell.com | support.dell.com show ip igmp interface View information on the a number from 1 to 4094. Command Modes EXEC EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 10-2. show ip igmp snooping mrouter Command Example FTOS#show ip igmp - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 127
Command Modes Command History Example EXEC EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 10-3. show ip igmp snooping mrouter Command Example FTOS#show ip igmp snooping mrouter vlan 2 Interface Router Ports Vlan 2 Po 128 FTOS# - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 128
www.dell.com | support.dell.com 126 | Internet Group Management Protocol (IGMP) - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 129
\ 11 Interfaces Overview This chapter defines interface commands and is divided into the following sections: • Port Interface Commands • Port Channel Commands • Time Domain Reflectometer (TDR) Commands Port Interface Commands The following commands are for physical, loopback, and null interfaces: - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 130
For more information on configuring and using Port Channels, refer to the Dell PowerEdge Configuration Guide for the M I/O Aggregator. Time Domain Reflectometer (TDR) Commands Time domain reflectormeter (TDR) is useful for troubleshooting an interface that is not establishing a link; either it is - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 131
auto vlan command adds the port as untagged to default vlan and tagged to all other 4K-1 VLAN. Information Command History Version 8.3.17.0 Supported on M I/O Aggregator clear counters Clear the counters used in the show interfaces commands for all VRRP groups, VLANs, and physical interfaces, or - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 132
www.dell.com | support.dell.com Parameters interface (OPTIONAL) Enter any of the following keywords and all interface counters. Command Modes EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 11-1. clear counters Command Example FTOS#clear counters - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 133
240 characters long. Defaults No description is defined. Command Modes INTERFACE Command History Usage Information Related Commands Version 8.3.17.0 Supported on M I/O Aggregator • Spaces between characters are not preserved after entering this command unless you enclose the entire description - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 134
www.dell.com | support.dell.com group Group two LAGs in a supergroup ("fate-sharing group" Modes Command History Example PORT-CHANNEL FAILOVER-GROUP (conf-po-failover-grp) Version 8.3.17.0 Supported on M I/O Aggregator Figure 11-2. group Command Example FTOS(conf)#port-channel failover-group FTOS - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 135
Command History Usage Information Example Version 8.3.17.0 Supported on M I/O Aggregator When creating an interface range, interfaces appear in the order they are entered; they are not sorted. The command verifies that interfaces are - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 136
www.dell.com | support.dell.com Example Figure 11-6 is an example of a single range bulk configuration. Figure 11-6. Single Range Bulk Configuration FTOS(conf)# interface range tengigabitethernet 5/1 - 23 FTOS( - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 137
Defaults none Command Modes CONFIGURATION Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage Figure 11-9 is an example of how to define an interface range macro named test. To display the macro Information definition, execute the show running-config command. Example Figure - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 138
www.dell.com | support.dell.com interface vlan Configure the default VLAN to enable transmitting data. Syntax keepalive Defaults Enabled Command Modes INTERFACE Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage When you configure keepalive, the system keeps the link is - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 139
by a number. Range: 1-128 Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage The delta column displays changes since monitor Command Menu Options Key systest-3 monitor time time Description Displays the host name assigned to the system. Displays the amount of time since the - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 140
www.dell.com | support.dell.com Table 11-2. monitor Command Menu Options Key Description m . Defaults Not configured. Command Modes INTERFACE VLAN Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator This CLI applies only to the Default VLAN. To display information - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 141
, enter no negotiation auto. Defaults Enabled Command Modes INTERFACE Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage The no negotiation auto command is only available if you first manually set the speed of a port to Information 10Mbits or 100Mbits. The negotiation auto - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 142
www.dell.com | support.dell.com Figure 11-14. Display Auto-negotiation Master/Slave Setting (partial) FTOS#show interfaces configured TenGigabitEthernet 13/18 is up, line protocol is up Hardware is Dell Force10Eth, address is 00:01:e8:05:f7:fc Current address is 00:01:e8:05:f7:fc Interface index is - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 143
configured interfaces (group). Syntax show config Command Modes CONFIGURATION INTERFACE (conf-if-range) Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 11-16. show config (Bulk Configuration) Command Example FTOS(conf)#interface range tengigabitethernet 1/1 - 2 FTOS - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 144
www.dell.com | support.dell.com show config (from PROTOCOL LLDP mode) Displays the LLDP information details over time for link monitoring when the rate-interval is configured for 5 seconds. Dell Force10 recommends using higher rate-intervals such as 15 to 299 seconds to minimize the errors seen - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 145
Example Figure 11-19. show interfaces Command Example for 10G Port FTOS#show interfaces tengigabitethernet 2/0 TenGigabitEthernet 2/0 is up, line protocol is up Hardware is Dell Force10Eth, address is 00:01:e8:05:f7:3a Interface index is 100990998 Internet address is 213.121.22.45/28 MTU 1554 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 146
www.dell.com | support.dell.com Table 11-4. Lines in show interfaces Command Example Line Input Statistics: Output Statistics: Rate information... Time since... Description Displays all the input statistics including: • - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 147
ManagementEthernet 0/0 is up, line protocol is up Hardware is DellForce10Eth, address is 00:1e:c9:f1:00 address is 10.11.209.87/16 Mode of IP Address Assignment : MANUAL DHCP Client-ID: mgmt001ec9f10005 Virtual-IP is not set Virtual-IP IPv6 17.0 Supported on M I/O Aggregator Interfaces | - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 148
support.dell.com Example Figure 11-21. show interfaces configured Command Example FTOS#show interfaces configured TenGigabitEthernet 1/1 is up, line protocol is down(error-disabled[UFD]) Hardware is DellForce10Eth, address is 00:01:e8:00:ab:01 Current address is 00:01:e8:00:ab:01 Server Port - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 149
slot and port number. OK? Indicates if the hardware is functioning properly. Status States whether the interface the interface. Description Displays the description (if any) manually configured for the interface. show interfaces port-channel 17.0 Supported on M I/O Aggregator Interfaces | 147 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 150
www.dell.com | support.dell.com Example Figure 11-23. show interfaces port-channel Command Example (EtherScale) FTOS#show interfaces port-channel Port-channel 1 is down, line protocol is down Hardware address is 00:1e:c9:f1:00:05, Current address is 00:1e:c9:f1:00:05 Interface index is 1107755009 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 151
Table 11-6. show interfaces port-channel Command Example Fields (continued) Field Output 0... Rate information... Time since... Description Displays the type and number of packets sent out the interface. This information is displayed over three lines. Displays the traffic rate information into and - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 152
www.dell.com | support.dell.com Command Modes Command History Example EXEC EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 11-25. show interfaces status Command Example FTOS#show interfaces stack-unit 0 TenGigabitEthernet 0/1 is down, line protocol is down Hardware is - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 153
Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 11-26. show interfaces status Command Example FTOS#show interface status number. Range: 0 to 5 Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Interfaces | 151 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 154
www.dell.com | support.dell.com Example Figure 11-27. show interfaces switchport Command Example FTOS#show interfaces switchport Codes: tagged the VLAN tagged ("True"), untagged ("False"), or hybrid ("Hybrid"), which supports both untagged and tagged VLANs by port 13/0. Lists the VLANs to which - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 155
Command Modes Command History Example none EXEC Version 8.3.17.0 Supported on M I/O Aggregator Figure 11-29. show tdr Status: Shorted Length: 93 (+/- 1) meters, Status: Open Status: Impedance Mismatch Definition TDR test is complete, no fault is detected on the cable, and the test - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 156
www.dell.com | support.dell.com Related Commands vlan tagged Runs the TDR test. show on the VLAN named is displayed. Command Modes EXEC EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 11-30. show vlan Command Example FTOS#show vlan Codes: * - - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 157
Table 11-10. show vlan Command Information Column Heading Status Q Ports Description Displays the word Inactive for inactive VLANs and the word Active for active VLANs. Displays G for GVRP tagged, M for member of a VLAN-Stack VLAN, T for tagged interface, U (for untagged interface), x ( - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 158
www.dell.com | support.dell.com shutdown Disable an interface. Syntax shutdown To activate an interface, enter no shutdown. Defaults The interface is disabled. Command Modes INTERFACE Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage The show tdr command marks a physical - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 159
either enabled or disabled. For speed settings of 1000 or auto, the software sets the link to auto-negotiation and you cannot change that setting. In none Command Modes EXEC Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator The interface must be enabled to run - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 160
www.dell.com | support.dell.com vlan tagged Add a Layer 2 interface to a VLAN as a tagged interface. in Layer 2 mode are untagged. Command Modes INTERFACE VLAN Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage Information When you use the no tagged command, the interface - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 161
/port information. Defaults All interfaces in Layer 2 mode are untagged. Command Modes INTERFACE VLAN Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator Untagged interfaces can only belong to one VLAN. In the default VLAN, you cannot use the no untagged interface - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 162
160 | Interfaces www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 163
debug ip dhcp • debug ip icmp • ip route • management route • show arp • show hosts • show ip management-route • show ip multicast-cam stack-unit • show ip interface • Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator debug ip dhcp Enable debug - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 164
www.dell.com | support.dell.com Defaults Debug disabled Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Example Figure 12-1. debug ip dhcp Command Example FTOS#debug ip dhcp 00:12:21 : %RELAY-I-PACKET: BOOTP REQUEST (Unicast) received at interface - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 165
) Enter the keyword tag followed by a number to assign to the route. Range: 1 to 4294967295 Defaults Not configured. Command Modes CONFIGURATION Command History Version 8.3.17.0 Supported on M I/O Aggregator IPv4 Routing | 163 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 166
in the hardware routing tables. Separate routing tables are maintained for IPv4 management routes. This command manages both tables. show hosts View the host table and DNS configuration. Syntax show hosts Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 167
domain service. If DNS is not enabled, the Name/Address lookup is static mapping. Lists the name servers, if configured. Displays the host name assigned to the IP address. Classifies the entry as one of the following: • perm - the entry was manually - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 168
dell.com | support.dell also. (OPTIONAL) Enter the keyword static to view entries entered manually. (OPTIONAL) Enter the keyword dynamic to view dynamic entries. ( Supported on M I/O Aggregator Figure 12-4. show arp Command Example (Partial) FTOS>show arp Protocol Address Age(min) Hardware - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 169
primary VLAN 10) in a PVLAN. Line 2 shows primary VLAN 10. Table 12-2. show arp Command Example Fields Row Heading Protocol Address Age(min) Hardware Address Interface VLAN CPU Description Displays the protocol type. Displays the IP address of the ARP entry. Displays the age in minutes of the - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 170
www.dell.com | support.dell.com show ip management-route View the IP addresses assigned to the Management active routes also. Command Modes Command History Example EXEC EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 12-7. show ip management route Command Example FTOS#show - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 171
route prefixes and the total number routes which can be entered in to CAM. Command Modes EXEC EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 12-8. show ip cam stack-unit Command Example FTOS#show ip multicast-cam stack-unit 0 port-set 0 10.10.10.10 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 172
www.dell.com | support.dell.com Parameter interface brief configuration (OPTIONAL) Enter the following default configurations only. Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Example Figure 12-9. show ip interface Command Example FTOS - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 173
and the associated slot and port number. Displays the IP address for the interface, if configured. Indicates if the hardware is functioning properly. Displays Manual if the configuration is read from the saved configuration. States whether the interface is enabled (up) or disabled (administratively - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 174
www.dell.com | support.dell.com Command Modes Command History Example EXEC EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 12-11. show ip route summary and show ip route static Command Examples FTOS#show ip route summary Route Source Active Routes - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 175
summarizing the IP routes in the switch. Syntax show ip route summary Command Modes Command History Example EXEC EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 12-12. show ip route summary Command Example FTOS>show ip route summary Route Source Active Routes Non-active - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 176
www.dell.com | support.dell.com Example Figure 12-13. show tcp statistics cp Command Example FTOS#show tcp statistics Rcvd: 9849 Total, 0 no port 0 checksum error, 0 bad offset, 0 too - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 177
Table 12-9. show tcp statistics cp Command Example Fields (continued) Field 355 ack... 0 window probe... 7 Connections initiated... 14 Connections closed... 20 Total rxmt... 0 Keepalive.... Description Displays the number of acknowledgement packets sent and the number of packet delayed. Displays - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 178
176 | IPv4 Routing www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 179
optimization enables quality-of-service (QoS) treatment for iSCSI storage traffic on an Aggregator. Note: When iSCSI storage devices are detected on the server-ports, storm-control Mode EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator iSCSI Optimization | 177 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 180
www.dell.com | support.dell.com Example Figure 13-1. show iscsi Command Example FTOS#show iscsi . Syntax show iscsi sessions Command Mode EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Example Figure 13-2. show iscsi sessions Command Example FTOS# show - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 181
ID to display detailed information on specified iSCSi session. Command Mode EXEC EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 13-3. show iscsi sessions detailed Command Example FTOS# show isci sessions detailed Session 0 : Target:iqn.2010 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 182
180 | iSCSI Optimization www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 183
Protocol (LACP) Overview This chapter contains commands for Dell Force10's implementation of the link aggregation control protocol ( EXEC Privilege Command History Related Commands Version 8.3.17.0 show lacp Supported on M I/O Aggregator Displays the LACP configuration Link Aggregation Control - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 184
www.dell.com | support.dell.com debug lacp Debug LACP (events). Syntax debug lacp [events | pdu interface [ port information. Defaults none Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator show lacp Displays the LACP matrix. Syntax show lacp - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 185
Example 1 Figure 14-1. show lacp port-channel-number Command Example FTOS#show lacp 128 Port-channel 1 admin up, oper up, mode lacp Actor System ID: Priority 32768, Address 0001.e800.a12b Partner System ID: Priority 32768, Address 0001.e801.45a5 Actor Admin Key 1, Oper Key 1, Partner Oper Key 1 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 186
www.dell.com | support.dell.com 184 | Link Aggregation Control Protocol (LACP) - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 187
. You can configure an IP address and Layer 3 protocols on a VLAN called Inter-VLAN routing. FTP, TFTP, ACLs, and SNMP are not supported on a VLAN. Occasionally, while sending broadcast traffic over multiple Layer 3 VLANs, the virtual router redundancy protocol (VRRP) state of a VLAN interface may - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 188
www.dell.com | support.dell.com clear mac-address-table dynamic Clear the MAC address ID number from 1 to 4094. Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator description Add a description about the selected VLAN. Syntax description description - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 189
by the VLAN ID to display the MAC address assigned to the VLAN. Range: 1 to 4094. Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Layer 2 | 187 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 190
188 | Layer 2 www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 191
make available a physical topology for network management. The Dell Fore10 operating software (FTOS) implementation of LLDP is based on IEEE , refer to the Link Layer Discovery Protocol chapter of the Dell PowerEdge Configuration Guide for the M I/O Aggregator. clear lldp counters Clear LLDP - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 192
www.dell.com | support.dell.com Parameters Defaults Command Modes Command History interface none EXEC Privilege Version 8.3.17.0 Enter the following keywords and slot/port or number information: • For a 10- - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 193
Defaults LLDP is not enabled on the interface. Command Modes INTERFACE (conf-if-interface-lldp) Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator You must enable LLDP globally from CONFIGURATION mode before you can configure it on an interface. This command places - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 194
www.dell.com | support.dell.com Defaults Command Modes Command History Example none EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 16-1. show lldp neighbors Command Example FTOS(conf-if-te-1/31)#do show lldp neighbors Loc PortID Rem Host Name Rem Port Id Rem Chassis Id - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 195
local area networks (VLANs) and port-channel interfaces do not support port monitoring. • The monitoring (destination, "MG") and monitored (source, "MD") ports must be on the same switch. • The monitored (source) interface must be a server-facing interface in the format slot/port, where valid slot - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 196
www.dell.com | support.dell.com Message 1 Assign a Monitored Port to More than One Monitoring Port FTOS(conf conf-mon-sess-session-ID) Command History Related Commands Version 8.3.17.0 monitor session Supported on M I/O Aggregator Enables a monitoring session. monitor session Create a session - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 197
Command Modes Command History Example CONFIGURATION Version 8.3.17.0 Supported on M I/O Aggregator Figure 17-1. monitor session Command SESSION (conf-mon-sess-session-ID) Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 17-2. show config Command Example FTOS(conf- - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 198
www.dell.com | support.dell.com Command Modes Command History Example EXEC EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 17-3. show monitor session Command Example FTOS#show monitor session 5 SessionID Source --------- ------ 5 Te 0/4 FTOS# Destination ---------- - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 199
Related Commands monitor session description Creates a session for monitoring. Displays a monitor session. Port Monitoring | 197 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 200
www.dell.com | support.dell.com source (port monitoring) Configure a port monitor source. Syntax source interface destination interface -sess-11)# Usage The monitored (source) interface must be a server-facing interface in the format slot/port, where valid Information slot numbers are 0-1 and - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 201
18 Quality of Service (QoS) Overview The Dell Force10 operating software (FTOS) commands for quality of service (QoS) include traffic conditioning and congestion control. This EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Quality of Service (QoS) | 199 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 202
www.dell.com | support.dell.com Example 1 Figure 18-1. show qos statistics Command Example FTOS#show qos -mapping Defaults none Command Modes EXEC EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 18-2. show qos wred-profile Command Example FTOS#show - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 203
the system: • enable password • enable restricted • enable smux-debug • service password-encryption • show users • username SSH Server and SCP Commands FTOS supports secure shell (SSH) protocol versions 1.5 and 2.0. SSH is a protocol for secure remote login over an insecure network. SSH sessions are - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 204
dell.com | support.dell that was already encrypted by a Dell Force10 router. Use this parameter only with a password show running-config file of another Dell Force10 router. Enter a text string Usage Information Version 8.3.17.0 Supported on M I/O Aggregator Use Dell Force10 technical support - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 205
clear text, use the no service password-encryption command. Defaults Enabled. Command Modes CONFIGURATION Command History Version 8.3.17.0 Supported on M I/O Aggregator Caution: Encrypting passwords with this command does not provide a high level of security. When the passwords are encrypted - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 206
dell.com | support.dell.com Usage Information To keep unauthorized people from viewing passwords in the switch configuration file, use the service FTOS#show ip ssh 2#show ip ssh SSH server SSH server version Password Authentication Hostbased Authentication RSA Authentication FTOS# - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 207
terminal lines in the switch. Command Modes Command History Example EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 19-4. show users Command Example FTOS#show user Line 0 console 0 * 3 vty 1 FTOS# User admin admin Host(s) idle idle Location 172.31.1.4 Security | 205 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 208
dell.com | support.dell.com Table 1 describes the information in the show users command example. Table 1 show users Command Description Field (untitled) Line User Host supports both inbound and outbound SSH sessions using IPv4 addressing. Inbound SSH supports Version 8.3.17.0 Supported on M I/O - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 209
8.3.17.0 Supported on M I/O Aggregator Usage To view the defined user names, use the show running-config user command. Information Related Commands service password-encryp tion show running-config Specifies a password for users on terminal lines. Views the current configuration. Security | 207 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 210
208 | Security www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 211
The SNMP command available in the Dell Force10 operating software (FTOS) is: • snmp-server community The SNMP is used to communicate your SNMP server to the following: - SNMP Timeout-greater than 3 seconds - SNMP Retry count-greater than 2 seconds • SNMP operations are not supported on a virtual - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 212
Command History Related Commands Version 8.3.17.0 show logging Supported on M I/O Aggregator Displays logging settings and system messages in the internal buffer. logging hostname Configure an IP address or host name of a Syslog server where logging messages will be sent. Multiple logging - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 213
: 40960 to 524288. Default: 40960 bytes. Defaults level = 7; size = 40960 bytes Command Modes CONFIGURATION Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator When you decrease the buffer size, all messages stored in the buffer are lost. Increasing the buffer size - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 214
www.dell.com | support.dell.com Related Commands clear logging logging hostname show logging Clears the Command History Related Commands Version 8.3.17.0 Supported on M I/O Aggregator logging hostname logging on Enables logging to a Syslog server. Enables logging. 212 | Simple Network - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 215
to be stored. Range: 0 to 500. Default: 1 message. Defaults 1 message Command Modes CONFIGURATION Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator When the number of messages reaches the limit you set with the logging history size command, older messages are - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 216
www.dell.com | support.dell.com logging monitor Specify which messages are logged to Telnet to logging buffer, Syslog server and terminal lines, use the no logging on command. Defaults Enabled Command Modes CONFIGURATION Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 217
the source IP address of Syslog packets sent to the Syslog server. Syntax logging source-interface interface To disable this command and Not configured. Command Modes CONFIGURATION Command History Version 8.3.17.0 Supported on M I/O Aggregator Usage Information Syslog messages contain the IP - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 218
www.dell.com | support.dell.com show logging Displays the logging settings and system messages logged to the internal buffer of : 0 to 1 Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator 216 | Simple Network Management Protocol (SNMP) and Syslog - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 219
Example 1 Figure 20-1. show logging Command Example FTOS#show logging Syslog logging: enabled Console logging: level debugging Monitor logging: level debugging Buffer logging: level debugging, 168 Messages Logged, Size (40960 bytes) Trap logging: level informational Logging to 172.16.1.162 Logging - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 220
www.dell.com | support.dell.com Example 3 Figure 20-3. show logging driverlog Command Example FTOS#show Supported on M I/O Aggregator Figure 20-4 configures a community named guest that is mapped to the security named guestuser with Read Only (ro) permissions. Example Figure 20-4. snmp-server - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 221
settings, use the terminal no monitor command. Defaults Disabled. Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Related Commands logging monitor Sets the logging parameters on the monitor/terminal. Simple Network Management Protocol - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 222
www.dell.com | support.dell.com 220 | Simple Network Management Protocol (SNMP) and Syslog - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 223
in the same chassis in a single stack. Up to three stacks are supported in an M1000e chassis. Stacking provides a single point of management and NIC feature, refer to the "Stacking Aggregators" chapter in the Dell Force10 Configuration Guide for the M I/O Aggregator. Stacking Commands You can use - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 224
www.dell.com | support.dell.com Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator This if the unit is in a problem state. Default Command Modes Command History Usage Information none EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Resetting the - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 225
the table to just the Interface and Connection fields. Defaults none Command Modes EXEC EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 21-2. show system stack-ports Command Example FTOS#show system stack-ports Topology: Daisy chain Interface - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 226
www.dell.com | support.dell.com Example Figure 21-4. show system stack-ports topology Command unit-number> iom-mode[configured] Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator show system stack-unit fanout Displays the current 40GbE ports configured - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 227
stack unit. Valid values: 0 to 5. Default: 0. Command Modes EXEC Privilege Command History Related Commands Version 8.3.17.0 reload show system Supported on M I/O Aggregator Reboots FTOS. Displays the current status of all stack members or a specific member. Example Figure 21-6. show system - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 228
www.dell.com | support.dell.com stack-unit iom-mode Toggle the M I/O Aggregator operating mode from standalone Command Modes CONFIGURATION Command History Related Commands Version 8.3.17.0 reload show system Supported on M I/O Aggregator Reboots FTOS. Displays the current status of all stack - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 229
Dell Force10 operating software (FTOS) storm control feature allows users to limit or suppress traffic during a traffic storm. Note: When iSCSI storage devices are detected on the server Modes Command History CONFIGURATION Version 8.3.17.0 Supported on M I/O Aggregator show io-aggregator - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 230
www.dell.com | support.dell.com Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 22-1. calendar set Command Example FTOS#show io-aggregator broadcast storm-control status Storm-Control Enabled Broadcast Traffic limited to 1000 Mbps FTOS# 228 | Storm Control - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 231
Force10 operating software (FTOS), the hardware, or using the network time protocol (NTP). With NTP, the switch can act only as a client to an NTP clock host. For more information, refer to the "Network Time Protocol" section of the Management chapter in the Dell Force10 Configuration Guide for the - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 232
www.dell.com | support.dell.com day year Enter the number of the day. Range: 1 to 31. set, the FTOS automatically updates the software clock after system bootup.You cannot delete the hardware clock (calendar). To manually update the software with the hardware clock, use the command clock read- - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 233
Modes EXEC Privilege Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator In the switch, the hardware clock is separate from the software and is called the calendar. This hardware clock runs continuously. After the hardware clock (the calendar) is set, the FTOS - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 234
configured Command Modes EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 23-5. clock set Command Example software clock. The software clock runs only when the software is up. The clock restarts, based on the hardware clock, when the switch reboots. Dell - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 235
add during the summer-time period. Range: 1 to1440. Default: 60 minutes Defaults Not configured. Command Modes CONFIGURATION Command History Related Commands Version 8.3.17.0 calendar set Supported on M I/O Aggregator Sets the hardware clock. System Time | 233 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 236
www.dell.com | support.dell.com clock summer-time recurring show clock Sets a date (and time zone) on which to convert the switch to daylight saving time each year. Displays the current clock settings. clock summer-time recurring Set the software clock to convert to daylight saving time on a - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 237
Not configured. Command Modes EXEC Privilege Command History Usage Information Version 8.3.17.0 Supported on M I/O Aggregator Use this command only if you are sure that the hardware clock is inaccurate and the software clock is correct. You cannot delete this command (that is, there is - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 238
www.dell.com | support.dell.com Related Commands calendar set Sets the hardware clock. 236 | System Time - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 239
24 Uplink Failure Detection (UFD) Overview Uplink failure detection (UFD) provides detection of the loss of upstream connectivity and, if used with network interface controller (NIC) teaming, automatic recovery from a failed link. UFD Commands The UFD commands are: • debug uplink-state-group • defer - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 240
www.dell.com | support.dell.com debug uplink-state-group Enable debug messages for events related to a specified uplink-state id values are 1 to 16. Defaults none Command Modes EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator 238 | Uplink Failure Detection (UFD) - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 241
Defaults None Command Modes Command History Usage Information UPLINK-STATE-GROUP-1 Version 8.3.17.4 Supported on M I/O Aggregator Use the defer-timer command to configure the defer timer that prevents unwanted flapping of server ports when the uplink port channel (LAG 128) goes down and comes up - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 242
www.dell.com | support.dell.com no enable Disable the default UFD link-tracking configuration. Syntax no enable Defaults All downstream server-facing ports are brought down when the upstream LAG 128 goes down. Command Modes UPLINK-STATE-GROUP-1 Command History Version 8.3.17.4 Supported on M - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 243
specified group. Valid group-id values are 1 to 16. Defaults none Command Modes EXEC EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Example Figure 24-1. show running-config uplink-state-group Command Example FTOS#show running-config uplink-state-group ! uplink - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 244
www.dell.com | support.dell.com show uplink-state-group Displays status information on a specified uplink group Defaults none Command Modes EXEC EXEC Privilege Command History Example Version 8.3.17.0 Supported on M I/O Aggregator Figure 24-2. show uplink-state-group Command Examples FTOS# - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 245
tracking. Syntax uplink-state group 1 Command Modes CONFIGURATION Command History Version 8.3.17.4 Supported on M I/O Aggregator Usage Information In some network topologies, you may prefer that server-facing ports on an Aggregator remain up and continue transmitting traffic without being - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 246
www.dell.com | support.dell.com 244 | Uplink Failure Detection (UFD) - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 247
Commands Offline Diagnostic Commands The offline diagnostics test suite is useful for isolating faults and debugging hardware. While tests are running, the Dell Force10 operating software (FTOS) results are saved as a text file (TestReport-SU-X.txt) in the flash directory. The show file command - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 248
www.dell.com | support.dell.com • show hardware stack-unit • show hardware system-flow clear hardware stack-unit Clear statistics from selected hardware components. Syntax clear hardware stack-unit 0-5 {counters | unit 0-1 counters | cpu data-plane statistics | cpu party-bus statistics | stack- - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 249
. Level 1 diagnostics is a smaller set of diagnostic tests with support for automatic partitioning. They perform status/self test for all the components Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator hardware watchdog Set the watchdog timer to trigger a reboot - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 250
History Version 8.3.17.0 Supported on M I/O Aggregator Usage Information This command enables a hardware watchdog mechanism that automatically reboots an FTOS switch/ router with a single unresponsive unit. This is a last resort mechanism intended to prevent a manual power cycle. offline stack - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 251
Command Modes Command History Example 1 Summary EXEC Privilege Version 8.3.17.0 Supported on M I/O Aggregator Figure 25-1. show diag information Command Example FTOS#show diag information Diag information: Diag software image version: 8-3-17-36 Stack-unit Member 0: Unit diags are - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 252
www.dell.com | support.dell.com Example 3 Figure 25-3. show diag testcase stack-unit Command Example FTOS#show diag testcase stack-unit 0 Navasota Diagnostics Test Test ID ------1 2 3 4 5 6 7 8 9 10 11 12 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 253
the data plane or management plane input and output statistics of the designated component of the designated stack member. Syntax show hardware stack-unit 0-5 {buffer [buffer unit | port [(1-56) | all] total buffer | buffer unit (1) port (1-56) queue [(0-14) | a11] buffer-info} {phy-firmware - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 254
www.dell.com | support.dell.com cpu for port-pipe 0, and then enter one of the following keywords to troubleshoot errors on the selected port-pipe and to give status on why a Supported on M I/O Aggregator Figure 25-5. show hardware stack-unit phy-firmware-version Command Example FTOS#show hardware - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 255
version" field represents loaded firmware version, and "SW version" represents SDK version. Figure 25-6. show hardware stack-unit cpu data-plane statistics Command Example FTOS#show hardware stack-unit 1 cpu data-plane statistics bc pci driver statistics for device: rxHandle :7392 noMhdr - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 256
www.dell.com | support.dell.com Example 5 Figure 25-9. show hardware stack-unit drops unit (drop summary per port) Command Example FTOS#show hardware stack-unit 1 drops unit 0 UserPort PortNumber Drops Egress Drops 1 1 0 2 2 0 3 3 0 4 4 0 5 5 5 6 6 0 7 7 0 8 8 0 9 9 0 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 257
Tag F GMII 1550 Tag F GMII 1550 Example 8 Figure 25-12. show hardware stack-unit unit 0 register Command Example FTOS#show hardware stack-unit 0 unit 0 register 0x0f180d34 ALTERNATE_EMIRROR_BITMAP_PARITY_CONTROL.ipipe0 = 0x00000001 0x0f180d35 ALTERNATE_EMIRROR_BITMAP_PARITY_STATUS_INTR.ipipe0 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 258
www.dell.com | support.dell.com Example 9 Figure 25-13. show hardware stack-unit unit details Command Example FTOS#show hardware stack-unit 0 unit 0 details The total no of FP & CSF Devices in the Card is 1 The total no of FP Devices in the Card is 1 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 259
ACL or QoS data for the selected stack member and stack member port-pipe. Syntax show hardware system-flow layer2 stack-unit 0-5 port-set 0-0 [counters] Parameters acl | qos stack- EXEC Privilege Command History Version 8.3.17.0 Supported on M I/O Aggregator Debugging and Diagnostics | 257 - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 260
www.dell.com | support.dell.com Example 1 Figure 25-17. show hardware system-flow layer2 counters Command Example FTOS#show hardware system-flow layer2 stack-unit 0 port-set 0 counters EntryId Description #HITS 2048 STP BPDU Redirects 0 2047 LLDP BPDU Redirects 164904 2045 LACP - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 261
system-flow layer2 (non-counters) Command Example FTOS#show hardware system-flow layer2 stack-unit 0 port-set 0 FP Entry for redirecting STP BPDU to CPU Port EID 2048: gid=1, slice=15, slice_idx=0x00, prio=0x800, - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 262
260 | Debugging and Diagnostics www.dell.com | support.dell.com - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 263
Definitions Symbol • ! U Type 0 3 C 4 5 8 Code Description Timeout (no reply) 3 echo reply destination unreachable: 0 network unreachable 1 host for network 1 redirect for host 2 redirect for type-of-service and network 3 redirect for type-of-service and host 0 echo request Query Error - Dell PowerEdge XL 5133-4 | Dell PowerEdge FTOS Command Line Reference Guide for - Page 264
dell.com | support.dell.com Table 26-1. ICMP Messages and Their Definitions Symbol & Type 9 10 11 12 13 14 15 16 17 18 Code Description 0 router advertisement 0 router solicitation time exceeded: 0 time-to-live equals 0 during transit 1 time-to-live equals 0 during reassembly parameter problem
Dell PowerEdge FTOS
Command Line Reference
Guide for the
M I/O Aggregator
Publication Date: March 2013