Dell PowerEdge XL 5133-4 Dell PowerEdge FTOS Command Line Reference Guide for - Page 104
show interface pfc detail Command Example, Table 7-3., Example, Usage, Information
View all Dell PowerEdge XL 5133-4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 104 highlights
www.dell.com | support.dell.com Example Figure 7-9. show interface pfc detail Command Example FTOS# show interfaces tengigabitethernet 0/49 pfc detail Interface TenGigabitEthernet 0/49 Admin mode is on Admin is enabled Remote is enabled Remote Willing Status is enabled Local is enabled Oper status is recommended PFC DCBX Oper status is Up State Machine Type is Feature TLV Tx Status is enabled PFC Link Delay 45556 pause quanta Application Priority TLV Parameters FCOE TLV Tx Status is disabled ISCSI TLV Tx Status is disabled Local FCOE PriorityMap is 0x8 Local ISCSI PriorityMap is 0x10 Remote FCOE PriorityMap is 0x8 Remote ISCSI PriorityMap is 0x8 0 Input TLV pkts, 1 Output TLV pkts, 0 Error pkts, 0 Pause Tx pkts, 0 Pause Rx pkts Usage Information Table 7-3 lists the show interface pfc summary field descriptions. Table 7-3. show interfaces pfc summary Command Example Fields Field Description Interface Interface type with stack-unit and port number. Admin mode is on Admin is enabled PFC mode: on or off. Priority list: list of the configured PFC priorities (if any). When the PFC admin mode is on, PFC advertisements are enabled to be sent and received from peers. Remote is enabled, Priority list, Remote Willing Status is enabled Remote Admin mode: (enabled if a valid TLV was received or disabled) Priority list: list of the configured PFC priorities (if any). Remote Willing Status: Willing bit received in PFC TLVs from the remote peer. Local is enabled Local PFC configuration including the mode and the list of PFC priorities configured. Operational status (local port) Port state for current operational PFC configuration: • Init: Local PFC configuration parameters were exchanged with the peer. • Recommend: Remote PFC configuration parameters were received from the peer. • Internally propagated: PFC configuration parameters were received from the configuration source. PFC DCBX Oper status Operational status for the exchange of the PFC configuration on the local port: match (up) or mismatch (down). State Machine Type Type of state machine used for DCBX exchanges of the PFC parameters: Feature - for legacy DCBX versions; Symmetric - for an IEEE version. TLV Tx Status Status of the PFC TLV advertisements: enabled or disabled. 102 | Data Center Bridging