Intel® Server Board S2600CP and Intel® Server System P4000CP Platform Management Intel® Server Board S2600CP and Server System P4000CP TPS No beep code due to uninstalled CPU. No monitoring of any sensors when on standby. No detection/logging of any ThermTrip faults. o These result as the system is shutdown by HW so BMC will not be available to detect that they occurred. Sensor monitoring after DC power-on will be delayed by the time it takes BMC to initialize its sensor subsystem (~15 to 20s), possibly losing SEL events or failing to provide correct FP LED status LED indication. Note: This delay occurs on each AC cycle even when EU Lot6 mode is disabled Chassis intrusion not detected when in standby 88 Revision 1.2 Intel order number G26942-003