Drive Hot-Swap Backplane Overview
View all Intel S2600CP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
Intel® Server System P4000CP Storage and Peripheral Drive Bays Intel® Server Board S2600CP and Server System P4000CP TPS Light pipes integrated into the drive tray assembly direct light emitted from Amber drive status and Green activity LEDs located next to each drive connector on the backplane, to the drive tray faceplate, making them visible from the front of the system. Amber Status LED Green Activity LED Table 59. 2.5" Hard Disk Drive Status LED States Amber Off Solid On Blink No access and no fault Hard Drive Fault has occurred RAID rebuild in progress (1 Hz), Identify (2 Hz) Table 60. 2.5" Hard Disk Drive Activity LED States Green Condition Power on with no drive activity Power on with drive activity Power on and drive spun down Power on and drive spinning up Drive Type SAS SATA SAS SATA SAS SATA SAS SATA Behavior LED stays on LED stays off LED blinks off when processing a command LED blinks on when processing a command LED stays off LED stays off LED blinks LED stays off 11.1.1 2.5" Drive Hot-Swap Backplane Overview The 8x2.5" backplane is attached to the back of the 8x2.5" drive bay assembly. On the front side of each backplane are mounted eight hard disk drive interface connectors (A), each providing both power and I/O signals to attached hard disk drives. Figure 40. 2.5" Backplane, Front Side 114 Revision 1.2 Intel order number G26942-003