Intel S2600CP Technical Product Specification - Page 193

Table 145. Integrated BMC Core Sensors

Page 193 highlights

Intel® Server Board S2600CP and Server System P4000CP TPS Appendix C: BMC Sensor Tables Note: All sensors listed below may not be present on all platforms. Please check platform EPS section for platform applicability and platform chassis section for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply). Table 145. Integrated BMC Core Sensors Full Sensor Name (Sensor name in SDR) Power Unit Status (Pwr Unit Status) Sensor Platform # Applicability 01h All Sensor Type Power Unit 09h Event/Readi Event Offset Triggers ng Type Sensor Specific 6Fh 00 - Power down 02 - 240 VA power down 04 - A/C lost 05 - Soft power control failure 06 - Power unit failure 00 - Fully Redundant Contrib. To System Status OK Assert/ De- assert Readable Value/Of fsets Event Data Fatal OK Fatal As and - Trig Offset De OK Rearm A Standby X 01 - Redundancy lost Degraded Power Unit Redundancy1 (Pwr Unit Redund) 02 - Redundancy degraded Degraded 02h Chassisspecific Power Unit 09h Generic 0Bh 03 - Non-redundant: sufficient resources. Transition from full redundant state. Degraded As and De - Trig Offset M X 04 - Non-redundant: sufficient resources. Transition from insufficient state. Degraded 05 - Non-redundant: insufficient resources Fatal Revision 1.2 177 Intel order number G26942-003

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228

Intel
®
Server Board S2600CP and Server System P4000CP TPS
Appendix C: BMC Sensor Tables
Revision 1.2
Intel order number G26942-003
177
Note
: All sensors listed below may not be present on all platforms. Please check platform EPS section for platform applicability and
platform chassis section for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate
hardware to support redundancy (for instance, fan or power supply).
Table 145. Integrated BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Readi
ng Type
Event Offset Triggers
Contrib. To
System Status
Assert/
De-
assert
Readable
Value/Of
fsets
Event
Data
Rearm
Stand-
by
Power Unit Status
(Pwr Unit Status)
01h
All
Power Unit
09h
Sensor
Specific
6Fh
00 - Power down
OK
As
and
De
Trig Offset
A
X
02 - 240 VA power
down
Fatal
04 - A/C lost
OK
05 - Soft power
control failure
Fatal
06 - Power unit failure
Power Unit Redundancy
1
(Pwr Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully Redundant
OK
As
and
De
Trig Offset
M
X
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degraded
04 – Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degraded
05 - Non-redundant:
insufficient resources
Fatal