Intel S2600CP Technical Product Specification - Page 195
Intel, Server Board S2600CP and Server System P4000CP TPS, Appendix C: BMC Sensor Tables, Revision 1
View all Intel S2600CP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 195 highlights
Intel® Server Board S2600CP and Server System P4000CP TPS Appendix C: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Sensor Platform # Applicability Button Sensor (Button) 09h All BMC Watchdog 0Ah All Voltage Regulator Watchdog (VR Watchdog) 0Bh All Fan Redundancy1 (Fan Redundancy) 0Ch Chassisspecific SSB Thermal Trip (SSB Therm Trip) 0Dh All Sensor Type Button/Switch 14h Mgmt System Health 28h Voltage 02h Fan 04h Temperature 01h Event/Readi Event Offset Triggers ng Type Contrib. To System Status Sensor Specific 6Fh Digital Discrete 03h Digital Discrete 03h Generic 0Bh Digital Discrete 03h 00 - Power Button 02 - Reset Button OK 01 - State Asserted Degraded 01 - State Asserted Fatal 00 - Fully redundant 01 - Redundancy lost 02 - Redundancy degraded 03 - Non-redundant: Sufficient resources. Transition from redundant 04 - Non-redundant: Sufficient resources. Transition from insufficient. 05 - Non-redundant: insufficient resources. 06 - Non-Redundant: degraded from fully redundant. 07 - Redundant degraded from nonredundant OK Degraded Degraded Degraded Degraded Non-Fatal Degraded Degraded 01 - State Asserted Fatal Assert/ De- assert Readable Value/Of fsets AS _ As - As and - De As and - De As and - De Event Data Trig Offset Trig Offset Trig Offset Trig Offset Trig Offset Rearm A A M A M Standby X X - X Revision 1.2 179 Intel order number G26942-003