Intel S2600CP Technical Product Specification - Page 141

Hot-swap Fans in Intel, Server Chassis, Table 64. Acoustic level for Intel, Server System

Page 141 highlights

Intel® Server Board S2600CP and Server System P4000CP TPS Intel® Server System P4000CP Thermal Management All the fans are Pulse Width Modulated (PWM) 6 wire/pin fans. The extra signals provide for fan redundancy and failure indications (Pwr, Gnd, Tach, PWM, Presence, and Failure). The fan headers are connected to motherboard with below sequence. Misconnection will potentially lead to thermal risk.  SYS FAN 1 connect to fan 1  SYS FAN 2 connect to fan 2  SYS FAN 3 connect to fan 3  SYS FAN 4 connect to fan 4  SYS FAN 5 connect to fan 5  SYS FAN 6 reserved  CPU 1 FAN reserved  CPU 2 FAN reserved  REAR FAN reserved Figure 50. Hot-swap Fans in Intel® Server Chassis 12.4.1 Acoustic The Intel® Server System P4308CP4MHGC and P4208CP4MHGCacoustic are measured with typical configuration and typical operating working conditions. Table 64. Acoustic level for Intel® Server System P4308CP4MHGC and P4208CP4MHGC System Configuration P4308CP4MHGC1,2 P4208CP4MHGC1,2 CPU 2x 130-W Memory 16x DR*8 HDD 4x3.5 Hotswap 4x2.5 Hotswap Add-in card 3x PCI Fans 5x Redundant 5x Redundant PSU 2x 750-W 2x 750-W Declared Acoustic OS idle:4.28 TO1: 4.39 3 TO2: 4.61 4 OS idle:4.28 TO1: 4.39 3 TO2: 4.61 4 Notes: 1. System is at or below 900m altitude and set to acoustic mode. Revision 1.2 125 Intel order number G26942-003

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228

Intel
®
Server Board S2600CP and Server System P4000CP TPS
Intel
®
Server System P4000CP Thermal Management
Revision 1.2
Intel order number G26942-003
125
All the fans are Pulse Width Modulated (PWM) 6 wire/pin fans. The extra signals provide for fan
redundancy and failure indications (Pwr, Gnd, Tach, PWM, Presence, and Failure). The fan
headers are connected to motherboard with below sequence. Misconnection will potentially lead
to thermal risk.
SYS FAN 1 connect to fan 1
SYS FAN 2 connect to fan 2
SYS FAN 3 connect to fan 3
SYS FAN 4 connect to fan 4
SYS FAN 5 connect to fan 5
SYS FAN 6 reserved
CPU 1 FAN reserved
CPU 2 FAN reserved
REAR FAN reserved
Figure 50. Hot-swap Fans in Intel
®
Server Chassis
12.4.1
Acoustic
The Intel
®
Server System P4308CP4MHGC and P4208CP4MHGCacoustic are measured with
typical configuration and typical operating working conditions.
Table 64. Acoustic level for Intel
®
Server System P4308CP4MHGC and P4208CP4MHGC
System Configuration
P4308CP4MHGC
1,2
P4208CP4MHGC
1,2
CPU
2x 130-W
Memory
16x DR*8
HDD
4x3.5 Hotswap
4x2.5 Hotswap
Add-in card
3x PCI
Fans
5x Redundant
5x Redundant
PSU
2x 750-W
2x 750-W
Declared Acoustic
OS idle:4.28
TO1: 4.39
3
TO2: 4.61
4
OS idle:4.28
TO1: 4.39
3
TO2: 4.61
4
Notes
:
1.
System is at or below 900m altitude and set to acoustic mode.