Intel S2600CP Technical Product Specification - Page 74

Address Resolution Protocol ARP: The BMC sends and responds to ARPs - + sdr

Page 74 highlights

Intel® Server Board S2600CP and Intel® Server System P4000CP Platform Management Intel® Server Board S2600CP and Server System P4000CP TPS  Chassis intrusion detection (dependent on platform support)  Basic fan control using Control version 2 SDRs  Fan redundancy monitoring and support  Power supply redundancy monitoring and support  Hot-swap fan support  Acoustic management: Support for multiple fan profiles  Signal testing support: The BMC provides test commands for setting and getting platform signal states.  The BMC generates diagnostic beep codes for fault conditions.  System GUID storage and retrieval  Front panel management: The BMC controls the system status LED and chassis ID LED. It supports secure lockout of certain front panel functionality and monitors button presses. The chassis ID LED is turned on using a front panel button or a command.  Power state retention  Power fault analysis  Intel® Light-Guided Diagnostics  Power unit management: Support for power unit sensor. The BMC handles powergood dropout conditions.  DIMM temperature monitoring: New sensors and improved acoustic management using closed-loop fan control algorithm taking into account DIMM temperature readings.  Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported on embedded NICs).  Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on embedded NICs).  Platform environment control interface (PECI) thermal management support  E-mail alerting  Embedded web server  Integrated KVM  Integrated Remote Media Redirection  Lightweight Directory Access Protocol (LDAP) support  Intel® Intelligent Power Node Manager support 6.1.1.3 New Manageability Features Intel® S2600CP Server Platforms offer a number of changes and additions to the manageability features that are supported on the previous generation of servers. The following is a list of the more significant changes that are common to this generation Integrated BMC based Intel® Server boards:  Sensor and SEL logging additions/enhancements (for example, additional thermal monitoring capability)  SEL Severity Tracking and the Extended SEL 58 Revision 1.2 Intel order number G26942-003

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228

Intel® Server Board S2600CP and Intel® Server System P4000CP Platform Management
Intel® Server Board S2600CP and Server System P4000CP TPS
Revision 1.2
Intel order number G26942-003
58
Chassis intrusion detection (dependent on platform support)
Basic fan control using Control version 2 SDRs
Fan redundancy monitoring and support
Power supply redundancy monitoring and support
Hot-swap fan support
Acoustic management: Support for multiple fan profiles
Signal testing support: The BMC provides test commands for setting and getting
platform signal states.
The BMC generates diagnostic beep codes for fault conditions.
System GUID storage and retrieval
Front panel management: The BMC controls the system status LED and chassis ID
LED. It supports secure lockout of certain front panel functionality and monitors button
presses. The chassis ID LED is turned on using a front panel button or a command.
Power state retention
Power fault analysis
Intel
®
Light-Guided Diagnostics
Power unit management: Support for power unit sensor. The BMC handles power-
good dropout conditions.
DIMM temperature monitoring: New sensors and improved acoustic management
using closed-loop fan control algorithm taking into account DIMM temperature
readings.
Address Resolution Protocol (ARP): The BMC sends and responds to ARPs
(supported on embedded NICs).
Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported
on embedded NICs).
Platform environment control interface (PECI) thermal management support
E-mail alerting
Embedded web server
Integrated KVM
Integrated Remote Media Redirection
Lightweight Directory Access Protocol (LDAP) support
Intel
®
Intelligent Power Node Manager support
6.1.1.3
New Manageability Features
Intel
®
S2600CP Server Platforms offer a number of changes and additions to the manageability
features that are supported on the previous generation of servers. The following is a list of the
more significant changes that are common to this generation Integrated BMC based Intel
®
Server boards:
Sensor and SEL logging additions/enhancements (for example, additional thermal
monitoring capability)
SEL Severity Tracking and the Extended SEL