Yamaha AW4416 Reference Guide - Page 42

Prefer.2 Make overall settings for the AW4416 2

Page 42 highlights

Prefer.2 page Make overall settings for the AW4416 (2) [Function] Set the rollback time, pre-roll/postroll time, and the nudge playback method etc. [Key operation] 1 • [UTILITY] key ¡ [F3] (Prefer.2) key 2 • Repeatedly press the [UTILITY] key until the screen shown at the right appears. 3 [Mouse operation] 4 M button ¡ UTIL button ¡ Pre- fer.2 tab UTILITY screen 5 6 7 8 [Screen functions] A GRID This sets the minimum unit when you specify an area in the EDIT screen TR Edit page or V.TR Edit page. For example if the grid value is set to "00:00:00.010," the specified location will move in 10 millisecond increments for each click of the [DATA/JOG] dial. (Default= 00:00:00.000) • The value you specify here will not affect how you adjust locate points (TRACK screen Mark Adj. page) or how you specify locate points using the [NUM LOCATE] key. • The value you specify here has no effect if "measure display" is selected as the counter display method. B ROLLBACK TIME This specifies the rollback time (0-5 seconds) of the [ROLL BACK] key. For details on rollback, refer to Operation Guide "Chapter 6. Transport/ locate operations." (Default= 5 seconds) C PREROLL/POSTROLL TIME Specify the pre-roll time (0-5 seconds) and post-roll time (0-5 seconds) used when you perform auto punch-in/out. For details on pre-roll time and post-roll time, refer to Operation Guide "Chapter 7. Punch-in/out." (Default= 5 seconds) D FL METER FINE Select one of the following two scales for the level meter/counter display. q NORMAL The full range of the level meter will indicate levels of -60 dB-0 dB. (Default setting) E S 78 F ms WORD CLOCK MTC SCENE 44.1k 48k LOCK MASTER INT EXT VARI SLAVE E -dB 0 FINE 2 6 10 12 14 20 18 30 20 42 26 60 9 10 11 12 13 14 15 16 LR READY INPUT -dB 0 2 6 12 20 30 42 60 LR READY INPUT q FINE The full range of the level meter will indicate levels of -26 dB-0 dB. This setting is convenient when you wish to make fine adjustments to the level near the 0 dB region. E S 78 F 9 10 ms WORD CLOCK MTC 44.1k 48k LOCK MASTER INT EXT VARI SLAVE SCENE E -dB 0 FINE 2 6 10 12 14 20 18 30 20 42 26 60 11 12 13 14 15 16 LR READY INPUT -dB 0 FINE 2 6 10 14 18 20 26 LR READY INPUT 35 - Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

UTILITY screen
— Reference Guide
35
Prefer.2 page
Make overall settings for the AW4416 (2)
[Function]
Set the rollback time, pre-roll/post-
roll time, and the nudge playback
method etc.
[Key operation]
[UTILITY] key
[F3] (Prefer.2)
key
Repeatedly press the [UTILITY]
key until the screen shown at the
right appears.
[Mouse operation]
M button
UTIL button
Pre-
fer.2 tab
[Screen functions]
A
GRID
This sets the minimum unit when you specify an
area in the EDIT screen TR Edit page or V.TR Edit
page. For example if the grid value is set to
00:00:00.010,
the speci
ed location will
move in 10 millisecond increments for each
click of the [DATA/JOG] dial. (Default=
00:00:00.000)
• The value you specify here will not affect
how you adjust locate points (TRACK screen
Mark Adj. page) or how you specify locate
points using the [NUM LOCATE] key.
• The value you specify here has no effect if
“measure display” is selected as the counter
display method.
B
ROLLBACK TIME
This speci
es the rollback time (0
5 seconds) of
the [ROLL BACK] key. For details on rollback,
refer to Operation Guide
Chapter 6. Transport/
locate operations.
(Default= 5 seconds)
C
PREROLL/POSTROLL TIME
Specify the pre-roll time (0
5 seconds) and
post-roll time (0
5 seconds) used when you per-
form auto punch-in/out. For details on pre-roll
time and post-roll time, refer to Operation
Guide
Chapter 7. Punch-in/out.
(Default= 5
seconds)
D
FL METER FINE
Select one of the following two scales for the
level meter/counter display.
NORMAL
The full range of the level meter will indicate
levels of
60 dB
0 dB. (Default setting)
FINE
The full range of the level meter will indicate
levels of
26 dB
0 dB. This setting is convenient
when you wish to make
ne adjustments to the
level near the 0 dB region.
5
6
7
8
1
2
3
4
8
9
13
14
15
16
10
11
12
–dB
0
2
6
20
30
42
60
10
14
18
20
26
12
FINE
READY
INPUT
L
R
S
F
ms
EXT
VARI
44.1k 48k
LOCK
WORD CLOCK
MTC
SCENE
SLAVE
MASTER
INT
E
7
–dB
0
2
6
20
30
42
60
12
READY
INPUT
L
R
E
8
9
13
14
15
16
10
11
12
–dB
0
2
6
20
30
42
60
10
14
18
20
26
12
FINE
READY
INPUT
L
R
S
F
ms
EXT
VARI
44.1k 48k
LOCK
WORD CLOCK
MTC
SCENE
SLAVE
MASTER
INT
E
7
–dB
10
14
18
20
26
FINE
READY
INPUT
L
R
E
0
2
6