Baud Rate, Protocol, Terminator
UPC - 086483075698
View all Sanyo VCC-HD5400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Switches 2 and 3 are not used. Settings in bold typeface in the table below show the factory default configurations. 1 Baud Rate Configure the transmission rate of connected devices to the transmission rate of the camera. Transmission Rate Switch 6 Switch 5 2400 OFF OFF 4800 ON OFF 9600 OFF ON 19200 ON ON When protocol is set to "PELCO", set to 2400. 2 Protocol Select the protocol for controlling the camera. Protocol Switch 4 Corresponding Protocol SSP (SANYO) OFF Automatic switching between Sanyo SSP and high speed SSP PELCO ON Automatic switching between PELCO-D and PELCO-P 3 Terminator If you connect multiple cameras, turn "ON" the terminator setting (switch 1) on the last device, and turn "OFF" those on all other devices. If you use the RS485 communication mode, assign a unique address (camera No.) to each camera. Configure the address by setting the dip switches to "ON" and "OFF". Configure the switches according to the List of Address Configuration Switches shown below. Circles in the list indicate "ON". Introduction 14/15