D-Link DGS-3130 User Manual - Page 334
DDM Temperature Threshold Settings
View all D-Link DGS-3130 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 334 highlights
DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide Figure 10-6 DDM Settings Window The fields that can be configured in DDM Global Settings are described below: Parameter Transceiver Monitoring Traps Alarm Transceiver Monitoring Traps Warning Description Select to enable or disable the transceiver monitoring traps alarm feature here. Select to enable or disable the transceiver monitoring traps warning feature here. Click the Apply button to accept the changes made. The fields that can be configured in DDM Shutdown Settings are described below: Parameter Unit From Port - To Port State Shutdown Description Select the Switch unit that will be used for this configuration here. Select the appropriate port range used for the configuration here. Use the drop-down menu to enable or disable the DDM state. Specify whether to shut down the port, when the operating parameter exceeds the Alarm or Warning threshold. Alarm - Shutdown the port when the configured alarm threshold range is exceeded. Warning - Shutdown the port when the configured warning threshold range is exceeded. None - The port will never shutdown regardless if the threshold ranges are exceeded or not. This is the default. Click the Apply button to accept the changes made. DDM Temperature Threshold Settings This window is used to display and configure the DDM Temperature Threshold Settings for specific ports on the Switch. To view the following window, click OAM > DDM > DDM Temperature Threshold Settings, as shown below: 324