Dell PowerEdge 2970 Hardware Owner's Manual - Page 23
CPU Init, CPU Machine Chk, PS # Missing, PS # Status, PS # Predictive, E161C, PS # Input Lost - processor
View all Dell PowerEdge 2970 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Table 1-6. LCD Status Messages (continued) Code E1421 E1422 E1610 E1614 E1618 E161C E1620 E1624 E1625 E1710 Text Causes Corrective Actions CPU Init The system BIOS has reported a See "Getting Help" on page 147. processor initialization error. CPU Machine Chk The system BIOS has reported a See "Getting Help" on page 147. machine check error. PS # Missing No power is available from the specified power supply; specified power supply is improperly installed or faulty. See "Troubleshooting Power Supplies" on page 122. PS # Status No power is available from the specified power supply; specified power supply is improperly installed or faulty. See "Troubleshooting Power Supplies" on page 122. PS # Predictive Power supply voltage is out of See "Troubleshooting Power acceptable range; specified power Supplies" on page 122. supply is improperly installed or faulty. PS # Input Lost Power source for specified power supply is unavailable, or out of acceptable range. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 122. PS # Input Range Power source for specified power supply is unavailable, or out of acceptable range. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 122. PS Redundancy The power supply subsystem is no See "Troubleshooting Power longer redundant. If the last Supplies" on page 122. supply fails, the system will go down. PS AC Current Power source is out of acceptable Check the AC power source. range. I/O Channel Chk The system BIOS has reported an See "Getting Help" on page 147. I/O channel check. About Your System 23