HP 9000 rp4410-4 User Service Guide, Fifth Edition - HP 9000 rp4410/4440 - Page 102

Installing the Server Into a Rack, Non-HP Rack, or Pedestal, HP Rack, Pedestal Mount

Page 102 highlights

Installing the Server Into a Rack, Non-HP Rack, or Pedestal The following information describes how to install the server into an HP rack. Information is also provided on approved non-HP rack and pedestal mount alternatives. HP Rack HP 9000 entry class servers that are installed into racks are shipped with equipment mounting slides. The Mid-Weight Slide Kit, (HP part number 5065-7291) is provided with each set of slides. Follow the steps in the kit installation guide to determine where and how to place the server into the rack. The following are additional instructions for installing the server into the rack: 1. The cable management arm (CMA) is factory-configured to mount on the left side of the server (as viewed from the rear of the chassis). You must switch the CMA from a left- to a right-mount configuration. To ensure easy removal of the power supplies, mount the CMA on the right side of the server. 2. You must remove two T120 screws from the server bezel; one screw from the same location on each side of the server. The screws are located behind the pull handles. Non-HP Rack Use the Mounting in non-HP racks guide for evaluating the installation of HP equipment in non-HP racks. The guide provides information to help you determine if you need to qualify whether you can install, maintain, and service any HP equipment in a non-HP rack. The guide is located on the HP website at: http://www.hp.com/racksolutions Select Mounting information from the menu and select the guide titled Mounting in non-HP racks. Pedestal Mount If you ordered the server as rackless, it has a pedestal pre-installed at the factory. If the server is a rack mount and you want to change it to a pedestal mount (rackless), you need an HP 9000 rp4440 Server Rackless Mount Kit. This kit comes with an installation guide titled Converting Your Rack Server to a Rackless Mount (HP part number A6979-96001). To convert a rack-mount server to a pedestal-mount server, see Converting Your Rack Server to a Pedestal Server on the HP website at: http://www.hp.com/ To attach the pedestal to the server, follow the instructions in the kit installation guide. Connecting the Cables This section describes the cables to connect to power the server and to provide LAN connectivity for the server. AC Input Power The HP 9000 rp4410 and rp4440 servers come with one or two power supplies installed. A power supply includes an ac input connector which is rated for 200 to 240 VAC at 13 amps. If two power supplies are installed, both power supplies must be connected separately to an ac power source. 102 Installing the System

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246

Installing the Server Into a Rack, Non-HP Rack, or Pedestal
The following information describes how to install the server into an HP rack. Information is
also provided on approved non-HP rack and pedestal mount alternatives.
HP Rack
HP 9000 entry class servers that are installed into racks are shipped with equipment mounting
slides. The
Mid-Weight Slide Kit
, (HP part number 5065-7291) is provided with each set of slides.
Follow the steps in the kit installation guide to determine where and how to place the server into
the rack.
The following are additional instructions for installing the server into the rack:
1.
The cable management arm (CMA) is factory-configured to mount on the left side of the
server (as viewed from the rear of the chassis). You must switch the CMA from a left- to a
right-mount configuration. To ensure easy removal of the power supplies, mount the CMA
on the right side of the server.
2.
You must remove two T120 screws from the server bezel; one screw from the same location
on each side of the server. The screws are located behind the pull handles.
Non-HP Rack
Use the
Mounting in non-HP racks
guide for evaluating the installation of HP equipment in non-HP
racks. The guide provides information to help you determine if you need to qualify whether you
can install, maintain, and service any HP equipment in a non-HP rack. The guide is located on
the HP website at:
Select
Mounting information
from the menu and select the guide titled
Mounting in non-HP
racks
.
Pedestal Mount
If you ordered the server as rackless, it has a pedestal pre-installed at the factory.
If the server is a rack mount and you want to change it to a pedestal mount (rackless), you need
an HP 9000 rp4440 Server Rackless Mount Kit. This kit comes with an installation guide titled
Converting Your Rack Server to a Rackless Mount
(HP part number A6979-96001).
To convert a rack-mount server to a pedestal-mount server, see
Converting Your Rack Server to a
Pedestal Server
on the HP website at:
To attach the pedestal to the server, follow the instructions in the kit installation guide.
Connecting the Cables
This section describes the cables to connect to power the server and to provide LAN connectivity
for the server.
AC Input Power
The HP 9000 rp4410 and rp4440 servers come with one or two power supplies installed. A power
supply includes an ac input connector which is rated for 200 to 240 VAC at 13 amps. If two power
supplies are installed, both power supplies must be connected separately to an ac power source.
102
Installing the System