HP 9000 rp4410-4 User Service Guide, Fifth Edition - HP 9000 rp4410/4440 - Page 241
C Physical and Environmental Specifications
View all HP 9000 rp4410-4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 241 highlights
C Physical and Environmental Specifications Table C-1 provides temperature and airflow information for minimum, typical, and maximum configurations for the HP 9000 rp4410 and rp4440 servers. It also lists the server and rack weights and dimensions. Table C-1 Physical and Environmental Specifications Min. Config. Max. Config. Typical Config. Condition Weight Typical Heat Release 180-264 VAC Airflow, Nominal Airflow, at Maximum Ambient degrees C1 Server Alone 410 Watts 297 250 425 88 lbs m3/hr CFM m3/hr (40 kg) 1368 Watts 175 CFM 1065 Watts Overall Server (W x D x H) Rack Pede-stal Rack Pede-stal 100 lbs 115 lbs (45.4 kg) (53 kg) W: 19 in (48.2 cm) D: 27.2 in (69.0 cm) H: 6.8 in (17.3 cm) W: 10.3 in (26.1 cm) D: 27.4 in (69.5 cm) H: 20.9 in (53.0 cm) ASHRAE Airflow cooling scheme (front to rear) Min./ One CPU, one power supply, 1 GB DIMM, zero DVD, Class 1 Config. one HDD, zero PCI cards, one core I/O. Max. Four CPUs, two power supplies, 128 GB DIMM, one Config. DVD, two HDD, six PCI cards, two core I/O. Typical Two CPUs, two power supplies, 16 GM DIMM, one Config. DVD, two HDD, two PCI cards, one core I/O. 1 Derate maximum dry bulb temperature 1 degree per 300 meters above 900 meters. 241