IBM x3655 Service Guide - Page 109

Installing, heat-sink, retention, module

Page 109 highlights

3. Disconnect all external cables and power cords. 4. Remove the cover (see "Removing the cover" on page 39). 5. Remove the riser-card assembly (see "Removing the riser-card assembly" on page 84). 6. Remove the air baffle; then, remove the heat sink and microprocessor (see "Removing the air baffle" on page 41 and "Removing a microprocessor" on page 87). 7. Remove the four screws that secure the heat-sink retention module to the system board; then, lift the heat-sink retention module from the system board. 8. If you are instructed to return the heat-sink retention module, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing a heat-sink retention module To install a replacement heat-sink retention module, complete the following steps: 1. Place the heat-sink retention module in the microprocessor location on the system board. 2. Install the four screws that secure the module to the system board Attention: Make sure that you install each heat sink with its paired microprocessor. Chapter 3. Removing and replacing server components 91

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

3.
Disconnect
all
external
cables
and
power
cords.
4.
Remove
the
cover
(see
“Removing
the
cover”
on
page
39).
5.
Remove
the
riser-card
assembly
(see
“Removing
the
riser-card
assembly”
on
page
84).
6.
Remove
the
air
baffle;
then,
remove
the
heat
sink
and
microprocessor
(see
“Removing
the
air
baffle”
on
page
41
and
“Removing
a
microprocessor”
on
page
87).
7.
Remove
the
four
screws
that
secure
the
heat-sink
retention
module
to
the
system
board;
then,
lift
the
heat-sink
retention
module
from
the
system
board.
8.
If
you
are
instructed
to
return
the
heat-sink
retention
module,
follow
all
packaging
instructions,
and
use
any
packaging
materials
for
shipping
that
are
supplied
to
you.
Installing
a
heat-sink
retention
module
To
install
a
replacement
heat-sink
retention
module,
complete
the
following
steps:
1.
Place
the
heat-sink
retention
module
in
the
microprocessor
location
on
the
system
board.
2.
Install
the
four
screws
that
secure
the
module
to
the
system
board
Attention:
Make
sure
that
you
install
each
heat
sink
with
its
paired
microprocessor.
Chapter
3.
Removing
and
replacing
server
components
91