IBM x3655 Service Guide - Page 178
actions
![]() |
UPC - 883436014533
View all IBM x3655 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 178 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. System event/error log message Action +1.8V critical under voltage fault Information only. The system real time clock battery is on longer Replace the battery. reliable +3.3V critical over voltage fault 1. Remove all PCI adapters. 2. Reinstall each PCI adapter, one at a time, restarting the server each time, to isolate a defective adapter. Replace any defective adapter. 3. If the error continues, (trained service technician only) replace the system board. +3.3V critical under voltage fault 1. Remove all PCI adapters. 2. Reinstall each PCI adapter, one at a time, restarting the sever each time, to isolate a defective adapter. replace any defective adapter. 3. If the error continues, (trained service technician only) replace the system board. 3.3V bus fault 1. Remove all PIC adapters. 2. Reinstall each PCI adapter, one at a time, restarting the server each time, to isolate a defective adapter. Replace any defective adapter. 3. If the system error continues, (trained service technician only) replace the system board. Power good fault 1. Reseat the power supplies. 2. If the error continues, replace the power backplane. Memory area non-critical over temperature warning 1. Make sure that the fans are operating and are not obstructed. 2. Make sure that the air baffles are in place and correctly installed. 3. Make sure that the server cover is installed and fully closed. Memory area non-recoverable over temperature fault 1. Make sure that the fans are operating and are not obstructed. 2. Make sure that the air baffles are in place and correctly installed. 3. Make sure that the server cover is installed and fully closed. 4. (Trained service technician only) Replace the system board. Fan n failure n = the fan number 1. Make sure that the connector on the fan is not damaged. 2. Make sure that the fan connector on the system board is not damaged. 3. Make sure that the fan is fully installed (press down on the fan). 4. Reseat fan n. 5. Replace fan n. 160 IBM System x3655 Type 7985: Problem Determination and Service Guide
![](/manual_guide/products/ibm-x3655-service-guide-079be7e/178.png)