IBM x3655 Service Guide - Page 69

Installing, ServeRAID, controller

Page 69 highlights

2. Turn off the server and all attached devices. 3. Disconnect all external cables and power cords. 4. Remove the cover (see "Removing the cover" on page 39). 5. Remove the fan-bracket assembly (see "Removing the fan-bracket assembly" on page 66). 6. Remove the riser-card assembly (see "Removing the riser-card assembly" on page 84). 7. Remove the air baffle (see "Removing the air baffle" on page 41). 8. Locate the ServeRAID SAS controller on the system board. 9. Move the SAS cable so it is not interfering with removing the ServeRAID SAS controller. 10. If the controller is a ServeRAID-8k SAS Controller, disconnect the battery from the card and remove the battery from the server. 11. Open the retaining clip on each end of the connector. 12. Lift the ServeRAID SAS controller out of the connector. 13. If you are instructed to return the ServeRAID SAS controller, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing a ServeRAID SAS controller To install the replacement ServeRAID-8k-l SAS controller or the ServeRAID-8k SAS controller, complete the following steps: Note: The following illustration shows installing a ServeRAID-8k SAS controller, the ServeRAID-8k-I SAS controller does not have a battery. Battery cable Battery RAID controller Battery mounting tabs Battery mounting clips Battery cable connector 1. Touch the static-protective package that contains the new ServeRAID SAS controller to any unpainted metal surface on the server. Then, remove the ServeRAID SAS controller from the package. Chapter 3. Removing and replacing server components 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

2.
Turn
off
the
server
and
all
attached
devices.
3.
Disconnect
all
external
cables
and
power
cords.
4.
Remove
the
cover
(see
“Removing
the
cover”
on
page
39).
5.
Remove
the
fan-bracket
assembly
(see
“Removing
the
fan-bracket
assembly”
on
page
66).
6.
Remove
the
riser-card
assembly
(see
“Removing
the
riser-card
assembly”
on
page
84).
7.
Remove
the
air
baffle
(see
“Removing
the
air
baffle”
on
page
41).
8.
Locate
the
ServeRAID
SAS
controller
on
the
system
board.
9.
Move
the
SAS
cable
so
it
is
not
interfering
with
removing
the
ServeRAID
SAS
controller.
10.
If
the
controller
is
a
ServeRAID-8k
SAS
Controller,
disconnect
the
battery
from
the
card
and
remove
the
battery
from
the
server.
11.
Open
the
retaining
clip
on
each
end
of
the
connector.
12.
Lift
the
ServeRAID
SAS
controller
out
of
the
connector.
13.
If
you
are
instructed
to
return
the
ServeRAID
SAS
controller,
follow
all
packaging
instructions,
and
use
any
packaging
materials
for
shipping
that
are
supplied
to
you.
Installing
a
ServeRAID
SAS
controller
To
install
the
replacement
ServeRAID-8k-l
SAS
controller
or
the
ServeRAID-8k
SAS
controller,
complete
the
following
steps:
Note:
The
following
illustration
shows
installing
a
ServeRAID-8k
SAS
controller,
the
ServeRAID-8k-I
SAS
controller
does
not
have
a
battery.
Battery
RAID controller
Battery mounting
clips
Battery mounting
tabs
Battery cable
Battery cable
connector
1.
Touch
the
static-protective
package
that
contains
the
new
ServeRAID
SAS
controller
to
any
unpainted
metal
surface
on
the
server.
Then,
remove
the
ServeRAID
SAS
controller
from
the
package.
Chapter
3.
Removing
and
replacing
server
components
51