IBM x3655 Service Guide - Page 69
Installing, ServeRAID, controller
![]() |
UPC - 883436014533
View all IBM x3655 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
2. Turn off the server and all attached devices. 3. Disconnect all external cables and power cords. 4. Remove the cover (see "Removing the cover" on page 39). 5. Remove the fan-bracket assembly (see "Removing the fan-bracket assembly" on page 66). 6. Remove the riser-card assembly (see "Removing the riser-card assembly" on page 84). 7. Remove the air baffle (see "Removing the air baffle" on page 41). 8. Locate the ServeRAID SAS controller on the system board. 9. Move the SAS cable so it is not interfering with removing the ServeRAID SAS controller. 10. If the controller is a ServeRAID-8k SAS Controller, disconnect the battery from the card and remove the battery from the server. 11. Open the retaining clip on each end of the connector. 12. Lift the ServeRAID SAS controller out of the connector. 13. If you are instructed to return the ServeRAID SAS controller, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing a ServeRAID SAS controller To install the replacement ServeRAID-8k-l SAS controller or the ServeRAID-8k SAS controller, complete the following steps: Note: The following illustration shows installing a ServeRAID-8k SAS controller, the ServeRAID-8k-I SAS controller does not have a battery. Battery cable Battery RAID controller Battery mounting tabs Battery mounting clips Battery cable connector 1. Touch the static-protective package that contains the new ServeRAID SAS controller to any unpainted metal surface on the server. Then, remove the ServeRAID SAS controller from the package. Chapter 3. Removing and replacing server components 51
![](/manual_guide/products/ibm-x3655-service-guide-079be7e/69.png)