v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 166-201-001 BMC indicates I2C errors on bus 1. 1. (Trained service technician only) Reseat the microprocessor. 2. Replace the following components one at a time, in the order shown, restarting the server each time: a. (Trained service technician only) Microprocessor b. (Trained service technician only) System board 166-201-002 BMC indicates I2C errors on bus 2. (Trained service technician only) Replace the system board. 166-201-003 BMC indicates I2C errors on bus 3. (Trained service technician only) Replace the system board. 166-201-004 BMC indicates I2C errors on bus 4. (Trained service technician only) Replace the system board. 166-201-005 BMC indicates I2C errors on bus 5. (Trained service technician only) Replace the system board. 166-201-006 BMC indicates I2C errors on bus 6. (Trained service technician only) Replace the system board. 166-201-007 BMC indicates I2C errors on bus 7. 1. (Trained service technician only) Reseat the microprocessor. 2. Replace the following components one at a time, in the order shown, restarting the server each time: a. (Trained service technician only) Microprocessor b. (Trained service technician only) System board 166-201-008 BMC indicates I2C errors on bus 8. 1. (Trained service technician only) Reseat the microprocessor. 2. Replace the following components one at a time, in the order shown, restarting the server each time: a. (Trained service technician only) Microprocessor b. (Trained service technician only) System board 166-250-000 System Management: Failed I2C cable is disconnected 1. Reconnect the I2C ribbon cable between the operator information panel assembly and the system board. 2. (Trained service technician only) Replace the system board. 150 IBM System x3655 Type 7985: Problem Determination and Service Guide
![](/manual_guide/products/ibm-x3655-service-guide-079be7e/168.png)