000 The server passed the test. Do not replace a CRU or FRU. 195 The Esc key was pressed to end the test. Do not replace a CRU or FRU. 197 This is a warning error, but it does not indicate a hardware failure; do not replace a CRU or FRU. Take the action that is indicated in the Action column but do not replace a CRU or a FRU. See the description of Warning in "Diagnostic text messages" on page 145 for more information. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 001-xxx-000 Failed core tests. (Trained service technician only) Replace the system board. 001-xxx-001 Failed core tests. (Trained service technician only) Replace the system board. 001-197-000 001-198-000 Test Aborted. 1. Check the test log for messages indicating the cause of the error, and take the indicated action. 2. Restart the server and run the diagnostic test again. 3. Run the Quick Memory Test All Banks diagnostic: then, if an error is detected, take the indicated action. 4. Reinstall and, if necessary, update the BIOS code on the server; then rerun the test (see "Updating the firmware" on page 17. 001-250-00n ECC test logic failed. See PC Doctor logs. Note: n = Failing CPU (1-2). 1. Restart the server. 2. Run the diagnostic test again. 3. (Trained service technician only) Replace the failing microprocessor. 005-xxx-000 Failed video test. 1. Reseat the optional video adapter, if one is installed. 2. (Trained service technician only) Replace the system board. 011-xxx-000 Failed COM1 serial port test. 1. Check the loopback plug that is connected to the externalized serial for; reseat or replace it if necessary. 2. Check the cable from the externalized serial port to the system board; reseat the cable if necessary. 3. (Trained service technician only) Replace the system board. 030-xxx-099 Failed internal SCSI interface test. (Trained service technician only) Replace the system board. 035-285-001 Adapter Communication error. 1. Update the ServeRAID SAS controller firmware. 2. Reseat the ServeRAID SAS controller. 3. Replace the ServeRAID SAS controller. Chapter 5. Diagnostics 147