IBM x3655 Service Guide - Page 160
Power-supply
![]() |
UPC - 883436014533
View all IBM x3655 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
LED SP DASD BRD FAN TEMP RAID PCI Problem The service processor has failed. Action Remove ac power from the server; then, reconnect the server to ac power and restart the server. Update the firmware on the BMC. If a Remote Supervisor Adapter II SlimLine is installed, update the firmware; if the problem remains, replace the adapter. A hard disk drive error has occurred. If the problem remains, replace the system board (trained service technician only). Check the LEDs on the hard disk drives and replace the indicated drive. If the problem remains, replace the hard disk drive backplane (trained service technician only). An error has occurred on the system board. v Check the LEDs on the system board to identify the component that is causing the error. v Check the system error log for information about the error. A fan has failed, is operating too slowly, Replace the failing fan, which is indicated by a lit LED on the or has been removed. The TEMP LED fan body. might also be lit. The system temperature has exceeded a threshold level. A failing fan can cause the TEMP LED to be lit. v Determine whether a fan has failed. If it has, replace it. v Make sure that the room temperature is not too high. See "Features and specifications" on page 4 for temperature information. v Make sure that the air vents are not blocked. A RAID controller error has occurred. Check the system error log for information about the error. An error has occurred on a PCI bus or v Check the LEDs on the PCI slots to identify the component on the system board. An additional LED that is causing the error. will be lit next to a failing PCI slot. v Check the system error log for information about the error. v If you cannot isolate the failing adapter through the LEDs and the information in the system error log, remove one adapter at a time from the failing PCI bus, and restart the server after each adapter is removed. If the problem remains, replace the following components, in the order shown, restarting the server each time: v PCI riser card v (Trained service technician only) System board Power-supply LEDs The following minimum configuration is required for the DC LED on the power supply to be lit: v Power supply v Power backplane v Power cord The following minimum configuration is required for the server to start: v One microprocessor v Two 512 MB DIMMs on the system board v One power supply v Power backplane v Power cord v RAID controller 142 IBM System x3655 Type 7985: Problem Determination and Service Guide
![](/manual_guide/products/ibm-x3655-service-guide-079be7e/160.png)