v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v SeeChapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Sensor type Sensor type code Byte definition and description OEM POST without time stamp 0xE0 Byte 4 POST Error/Event Type 0x00 POST PCI POST Event/Error 0x01 POST PCI Processor Event 0x02 POST Memory Error 0x04 POST Bus Event 0x05 POST Chipset Event OEM SMI handler with time stamp 0xC1 Byte 11 SMI Error/Event Type 0x00 SMI PCI Event/Error 0x01 SMI Processor Event/Error 0x02 SMI Memory Event/Error 0x04 SMI Bus Event/Error 0x05 SMI Chipset Event/Error OEM SMI handler without time stamp 0xE1 Byte 4 SMI Error/Event Type 0x00 SMI PCI Event/Error 0x01 SMI Processor Event/Error 0x02 SMI Memory Event/Error 0x04 SMI Bus Event/Error 0x05 SMI Chipset Event/Error 174 IBM System x3655 Type 7985: Problem Determination and Service Guide