IBM x3655 Service Guide - Page 166
solved.
![]() |
UPC - 883436014533
View all IBM x3655 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 166 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 035-286-001 Adapter CPU Test Error. 1. Update the ServeRAID SAS controller firmware. 2. Reseat the ServeRAID SAS controller. 3. Replace the ServeRAID SAS controller. 035-287-001 Adapter Local RAM Test Error. 1. Update the ServeRAID SAS controller firmware. 2. Reseat the ServeRAID SAS controller. 3. Replace the ServeRAID SAS controller. 035-288-001 Adapter NVSRAM Test Error. 1. Update the ServeRAID SAS controller firmware. 2. Reseat the ServeRAID SAS controller. 3. Replace the ServeRAID SAS controller. 035-289-001 Adapter Cache Test Error. 1. Update the ServeRAID SAS controller firmware. 2. Reseat the ServeRAID SAS controller. 3. Replace the ServeRAID SAS controller. 035-292-001 Adapter Parameter Set Error. 1. Update the ServeRAID SAS controller firmware. 2. Reseat the ServeRAID SAS controller. 3. Replace the ServeRAID SAS controller. 035-230-001 Battery Low. Replace the battery module on the ServeRAID SAS controller. 035-231-001 Abnormal Battery Temperature. Replace the battery module on the ServeRAID SAS controller. 035-231-001 Battery Status Unknown. Replace the battery module on the ServeRAID SAS controller. 089-xxx-0nn Failed microprocessor test Note: nn = APIC ID for failing microprocessor v 0, 1 = microprocessor 1 v 2, 3 = microprocessor 2 1. Make sure that the BIOS code is at the latest level. 2. (Trained service technician only) Reseat the microprocessor. 3. (Trained service technician only) Replace the microprocessor. 166-051-000 System Management: Failed Unable to communicate with Remote Supervisor Adapter II SlimLine 1. Update the firmware (BIOS, service processor, diagnostics) to the latest level. 2. Run the diagnostic test again. 3. Correct other error conditions (including failed system management tests and items that are logged in Remote Supervisor Adapter II SlimLine system event/error log) and run the test again. 4. Disconnect all power cords and external cables from the server, wait 30 seconds, reconnect the power cords and cables, and run the test again. 5. Reseat the Remote Supervisor Adapter II SlimLine. 6. Replace the Remote Supervisor Adapter II SlimLine. 148 IBM System x3655 Type 7985: Problem Determination and Service Guide
![](/manual_guide/products/ibm-x3655-service-guide-079be7e/166.png)