IBM x3655 Service Guide - Page 170
preceded
![]() |
UPC - 883436014533
View all IBM x3655 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 170 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 166-407-001 System Management: Failed BMC indicates failure in I2C bus test. 1. Disconnect all power cords and external cables from the server, wait 30 seconds, reconnect the power cords and cables, and retry the test. 2. Update the BMC firmware to the latest level. 3. Reseat the operator information panel cable. 4. Replace the following components one at a time, in the order shown, restarting the server each time: a. Operator information panel assembly b. (Trained service technician only) System board 166-nnn-001 System Management: Failed Note: nnn indicates the failure type. v 300 to 320: Self-test failure 1. Disconnect all power cords and external cables from the server, wait 30 seconds, reconnect the power cords and cables, and retry the test. v 400 to 420 (excluding 412, 414, and 415): 2. Update the BMC firmware to the latest level. I2C bus test failure 3. (Trained service technician only) Replace the system board. 166-412-001 System Management: Failed I2C bus failure. 1. Disconnect all power cords and external cables from the server, wait 30 seconds, reconnect the power cords and cables, and retry the test. 2. Update the BMC firmware to the latest level. 3. Reseat the power backplane. 4. Replace the following components one at a time, in the order shown, restarting the server each time: a. (Trained service technician only) Power backplane b. (Trained service technician only) System board 166-414-001 System Management: Failed I2C bus failure. 1. Disconnect all power cords and external cables from the server, wait 30 seconds, reconnect the power cords and cables, and retry the test. 2. Update the BMC firmware to the latest level. 3. Reseat the hard disk drive cable. 4. Replace the following components one at a time, in the order shown, restarting the server each time: a. (Trained service technician only) Hard disk drive backplane b. (Trained service technician only) System board 152 IBM System x3655 Type 7985: Problem Determination and Service Guide
![](/manual_guide/products/ibm-x3655-service-guide-079be7e/170.png)