IBM x3655 Service Guide - Page 173
performed
![]() |
UPC - 883436014533
View all IBM x3655 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 173 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 215-xxx-000 Failed CD-RW/DVD drive test. 1. Run the test again with a different CD-RW/DVD drive. 2. Reseat the following components: a. CD-RW/DVD drive b. Operator information panel assembly 3. Replace the following components one at a time, in the order shown, restarting the server each time: a. CD-RW/DVD drive b. CD-RW/DVD media backplane 217-198-xxx Could not establish drive parameters. 1. Reseat the hard disk drive signal cable. 2. Reseat the hard disk drive. 3. Replace the following components in the order shown, restarting the server each time: a. Hard disk drive b. Hard disk drive signal cable c. Hard disk drive backplane 217-xxx-00n Failed fixed disk test. Note: n is the number of the failed drive. The hard disk drive numbers are on the server front. 1. Reseat the hard disk drive indicated by n. 2. Replace the hard disk drive indicated by n. 301-xxx-000 Failed keyboard test. Note: After installing a USB keyboard, you might have to use the Configuration/Setup Utility program to enable keyboardless operation and prevent the POST error message 301 from being displayed during startup. 1. Reseat the keyboard cable. 2. Replace the following components one at a time, in the order shown, restarting the server each time: a. Keyboard b. (Trained service technician only) System board 405-xxx-000 Failed Ethernet test on Ethernet controller. 1. Run the Configuration/Setup Utility program and make sure that Ethernet is not disabled and that the BIOS code is at the latest level. 2. (Trained service technician only) Replace the system board. 405-xxx-00n Failed Ethernet test on adapter in PCI slot n. 1. Reseat the Ethernet adapter in slot n. 2. Replace the Ethernet adapter in slot n. 3. (Trained service technician only) Replace the system board. Chapter 5. Diagnostics 155
![](/manual_guide/products/ibm-x3655-service-guide-079be7e/173.png)