IBM x3655 Service Guide - Page 176
event/error
![]() |
UPC - 883436014533
View all IBM x3655 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 176 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. System event/error log message Action +12V critical over voltage fault 1. If the OVER SPEC LED on the light path diagnostics panel is lit, or any of the four power channel error LEDs (A, B, C, or D) on the system board are lit, see the entries about power-channel error LEDs in "Power problems" on page 135. (See "System-board LEDs" on page 15). 2. If the actions in "Power problems" on page 135do not identify a defective component, complete the following steps: a. Remove the power supplies. Replace the power supplies one at a time, restarting the server each time, to isolate a failing power supply. b. If the server fails to start, replace the power backplane. Restart the server. c. If the server fails to start, (trained service technician only) replace the system board. +12V critical under voltage fault 1. If the OVER SPEC LED on the light path diagnostics panel is lit, or any of the four power channel error LEDs (A, B, C, or D) on the system board are lit, see the entries about power-channel error LEDs in "Power problems" on page 135. (See "System-board LEDs" on page 15). 2. If the actions in "Power problems" on page 135do not identify a defective component, complete the following steps: a. Remove the power supplies. Replace the power supplies one at a time, restarting the server each time, to isolate a failing power supply. b. If the server fails to start, replace the power backplane. Restart the server. c. If the server fails to start, (trained service technician only) replace the system board. +12V planar fault 1. If the OVER SPEC LED on the light path diagnostics panel is lit, or any of the four power channel error LEDs (A, B, C, or D) on the system board are lit, see the entries about power-channel error LEDs in "Power problems" on page 135. (See "System-board LEDs" on page 15). 2. If the actions in "Power problems" on page 135do not identify a defective component, complete the following steps: a. Remove the power supplies. Replace the power supplies one at a time, restarting the server each time, to isolate a failing power supply. b. If the server fails to start, replace the power backplane. Restart the server. c. If the server fails to start, (trained service technician only) replace the system board. 158 IBM System x3655 Type 7985: Problem Determination and Service Guide
![](/manual_guide/products/ibm-x3655-service-guide-079be7e/176.png)