IBM x3655 Service Guide - Page 179
column
UPC - 883436014533
View all IBM x3655 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 179 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. System event/error log message Action Fan n fault n = the fan number 1. Make sure that the connector on the fan is not damaged. 2. Make sure that the fan connector on the system board is not damaged. 3. Make sure that the fan is fully installed (press down on the fan). 4. Reseat fan n. 5. Replace fan n. Hard drive n fault n = the hard disk drive number 1. Reseat hard disk drive n. 2. Replace hard disk drive n. Hard drive n removal detected n = the hard disk drive number Reseat hard disk drive n. HT1000 initiated sync flood: Legacy I/O Failure (Trained service technician only) Replace the system board. HT1000 initiated sync flood: PERR on PCI-x slot 1. Reseat the failing adapter. 2. Replace the failing adapter. 3. (Trained service technician only) Replace the system board. HT1000 initiated sync flood: SERR on PCI-x slot 1. Reseat the failing adapter. 2. Replace the failing adapter. 3. (Trained service technician only) Replace the system board. Power supply n removed n = the power supply number 1. Reseat power supply n. 2. Replace power supply n. 3. Replace the power backplane. Power supply n fault n = the power supply number 1. If the server power-on LED is lit, perform the following steps: a. Reduce the server to the minimum configuration (see "Solving undetermined problems" on page 177 for a description of the minimum configuration). b. Reinstall the components you removed, one at a time, restarting the server each time. c. If the error recurs, the component you just reinstalled is defective; replace the defective component. 2. Reseat the following components: a. Power supply n b. Power backplane 3. Replace the components listed in step 2, one at a time, in the order shown, restarting the server each time. Power supply n AC power removed n = the power supply number 1. Make sure that the power cords are correctly connected to the server and to a working electrical outlet. 2. Replace power supply n. 3. Replace the power backplane. Chapter 5. Diagnostics 161