IBM x3655 Service Guide - Page 167
x3655
UPC - 883436014533
View all IBM x3655 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, System x3655, Type 7985," on page 97 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 166-060-000 System Management: Failed. Unable to communicate with Remote Supervisor Adapter II SlimLine. 1. Update the firmware (BIOS, service processor, diagnostics) to the latest levels. 2. Run the diagnostic test again. 3. Correct other error conditions (including failed system management tests and items that are logged in Remote Supervisor Adapter II SlimLine system event/error log) and run the test again. 4. Disconnect all power cords and external cables from the server, wait 30 seconds, reconnect the power cords and cables, and run the test again. 5. Reseat the Remote Supervisor Adapter II SlimLine. 6. Replace the Remote Supervisor Adapter II SlimLine. 166-070-000 System Management: Failed Unable to communicate with Remote Supervisor Adapter II SlimLine 1. Update the firmware (BIOS, service processor, diagnostics) to the latest level. 2. Run the diagnostic test again. 3. Correct other error conditions (including failed system management tests and items that are logged in Remote Supervisor Adapter II SlimLine system event/error log) and run the test again. 4. Disconnect all power cords and external cables from the server, wait 30 seconds, reconnect the power cords and cables, and run the test again. 5. Reseat the Remote Supervisor Adapter II SlimLine. 6. Replace the Remote Supervisor Adapter II SlimLine. 166-198-000 System Management: Aborted 1. Run the diagnostic test again. 2. Correct other error conditions (including failed system management tests and items logged in the BMC error log and the system event/error log) and retry the test. 3. Disconnect all server and option power cords from the server, wait 30 seconds, reconnect the power cords, and retry the test. 4. Replace the Remote Supervisor Adapter II SlimLine, if installed. 5. (Trained service technician only) Replace the system board. 166-201-000 BMC indicates I2C errors on bus 0. (Trained service technician only) Replace the system board. Chapter 5. Diagnostics 149