Intel SE7525GP2 Product Specification - Page 152
Intel, Light-Guided Diagnostics
View all Intel SE7525GP2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
Error Reporting and Handling Intel® Server Boards SE7320SP2 and SE7525GP2 6.3.8 Memory Error Codes Table 70. Memory Error Codes Tpoint 001h 002h 0E1h 0E2h 0E3h 0E4h 0E5h 0E6h 0E8h 0E9h 0EAh 0EBh 0ECh 0EDh 0EEh 0EFh 0F0h 0F1h 0F2h 0F3h 0F4h Description MEM_ERR_CHANNEL_B_OFF (DIMM mismatch forced Channel B disabled) MEM_ERR_CK_PAIR_OFF (Slow DIMM(s) forced clock pair disabled) MEM_ERR_NO_DEVICE (No memory installed) MEM_ERR_TYPE_MISMATCH MEM_ERR_UNSUPPORTED_DIMM (Unsupported DIMM type) MEM_ERR_CHL_MISMATCH MEM_ERR_SIZE_MISMATCH MEM_ERR_ECC_MISMATCH MEM_ERR_ROW_ADDR_BITS MEM_ERR_INTERNAL_BANKS MEM_ERR_TIMING MEM_ERR_INST_ORDER_ERR MEM_ERR_NONREG_MIX MEM_ERR_LATENCY MEM_ERR_NOT_SUPPORTED MEM_ERR_CONFIG_NOT_SUPPORTED SYS_FREQ_ERR (Flag for Unsupported System Bus Freq) DIMM_ERR_CFG_MIX (Usupported DIMM mix) DQS_FAILURE (indicates DQS failure) MEM_ERR_MEM_TEST_FAILURE (Error code for unsuccessful Memory Test) MEM_ERR_ECC_INIT_FAILURE (Error code for unsuccessful ECC and Memory Initialization) 6.4 Intel® Light-Guided Diagnostics The server board provides system fault/status LEDs in many areas of the board to alert users to a particular failure or status of a component on the board. There are fault LEDs for the memory DIMMs and processors, and status LEDs for 5-volt stand-by and system state. 140 Revision 4.0