Intel SE7525GP2 Product Specification - Page 168

Serial Port Connector

Page 168 highlights

Connector Definitions and Pin-outs Intel® Server Boards SE7320SP2 and SE7525GP2 7.13 Serial Port Connector Two serial ports are provided on the SE7320SP2 and Server Board SE7525GP2. ƒ A standard, external DB9 serial connector is located on the back edge of the server board to supply a Serial A interface. And this connector is combined with VGA connector (J4) ƒ A Serial B port is provided through a 9-pin header (J15) on the server board. The following tables detail the pin-outs of these two ports. Table 90. External DB9 Serial A Port Pin-out (J8A1) Signal Name SERIAL_DCD1_FB SERIAL_RX1_FB SERIAL_TX1_FB SERIAL_DTR1_FB GND Pin Pin Signal Name T1 T6 SERIAL_DSR1_FB T2 T7 SERIAL_RTS1_FB T3 T8 SERIAL_CTS1_FB T4 T9 SERIAL_RING1_FB T5 Table 91. 9-pin Header Serial B Port Pin-out (J15) Signal Name SERIAL_DCD2_FB SERIAL_RX2_FB SERIAL_TX2_FB SERIAL_DTR2_FB GND Pin Pin Signal Name 1 2 SERIAL_DSR2_FB 3 4 SERIAL_RTS2_FB 5 6 SERIAL_CTS2_FB 7 8 SERIAL_RING2_FB 9 10 Key 156 Revision 4.0

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

Connector Definitions and Pin-outs
IntelĀ® Server Boards SE7320SP2 and SE7525GP2
Revision 4.0
156
7.13 Serial Port Connector
Two serial ports are provided on the SE7320SP2 and Server Board SE7525GP2.
A standard, external DB9 serial connector is located on the back edge of the server
board to supply a Serial A interface. And this connector is combined with VGA connector
(J4)
A Serial B port is provided through a 9-pin header (J15) on the server board.
The following tables detail the pin-outs of these two ports.
Table 90. External DB9 Serial A Port Pin-out (J8A1)
Signal Name
Pin
Pin
Signal Name
SERIAL_DCD1_FB
T1
T6
SERIAL_DSR1_FB
SERIAL_RX1_FB
T2
T7
SERIAL_RTS1_FB
SERIAL_TX1_FB
T3
T8
SERIAL_CTS1_FB
SERIAL_DTR1_FB
T4
T9
SERIAL_RING1_FB
GND
T5
Table 91. 9-pin Header Serial B Port Pin-out (J15)
Signal Name
Pin
Pin
Signal Name
SERIAL_DCD2_FB
1
2
SERIAL_DSR2_FB
SERIAL_RX2_FB
3
4
SERIAL_RTS2_FB
SERIAL_TX2_FB
5
6
SERIAL_CTS2_FB
SERIAL_DTR2_FB
7
8
SERIAL_RING2_FB
GND
9
10
Key