Konica Minolta AccurioPress C2070/2070P IC-314 User Guide - Page 122
Save In, File name, File of type, PASSED - The measured chart is by the standard, tolerances, Print
View all Konica Minolta AccurioPress C2070/2070P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
112 Chapter 7-Managing color 18. In the Save In list, select the folder to which the report must be saved. 19. In the File name box, modify the default name of the file. 20. In the File of type list, select the type of file for the report. 21. Click Save. A report according to ISO/DIS 12647-8 for digital systems is automatically be generated. The following is an example of a report showing that the validation was successful. Note: If the validation was unsuccessful, the following message appears at the top of the report page in red FAILED - The measured chart is not by the standard tolerances, and a red check mark appears in the results column for the categories that did not pass. The report includes the following information: ● Validation result: ○ PASSED - The measured chart is by the standard tolerances-This message appears at the top of the report in green. ○ FAILED - The measured chart is not by the standard tolerances-This message appears at the top of the report in red. ● General Information about the Printer name, Media type, Reference files name, dE type, and ISO standard ● Test categories, dE\dH tolerances, dE\dH measured values, and Pass\Fail results. ● A list of 100 patches showing the CMYK, Index #, L.a.b. reference values, actual measured values, and the dE. 22. Click Print to print the report. When printing the report, you can choose to save it as a PDF, if required.