Konica Minolta AccurioPress C2070/2070P IC-314 User Guide - Page 58
Using the Konica Minolta FD‑5/FD‑7 spectrophotometer to create a calibration table
View all Konica Minolta AccurioPress C2070/2070P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
48 Chapter 3-Calibration When the driver installation successfully completes, you are ready to use the Konica Minolta FD‑5/FD‑7 spectrophotometer to create a calibration table. When connected to the IC‑314 print controller version 1.0, the instrument automatically enters communication mode and Communicating... appears on the instrument's LCD screen. At this time the instrument's control buttons and measuring button are disabled. When the command to enable the measuring button is used from the IC‑314 print controller version 1.0 for the instrument, the measuring button can be used to measure the calibration chart. Using the Konica Minolta FD‑5/FD‑7 spectrophotometer to create a calibration table Requirements: ● Your FD‑5/FD‑7 spectrophotometer must be connected to the USB port on the IC‑314 print controller version 1.0. Turn on the device. If this is the first time you are connecting the device to the IC‑314 print controller version 1.0, the driver is automatically installed. ● The Print queue must be ready for printing (not suspended), and the printer must be warmed up.