Connecting the X-Rite i1/iSis/i1iO spectrophotometer to the IC‑314 print controller version 1.0
View all Konica Minolta AccurioPress C2070/2070P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
28 Chapter 3-Calibration Connecting the X-Rite i1/iSis/i1iO spectrophotometer to the IC‑314 print controller version 1.0 Before you connect the X-Rite iSis or i1iO to the IC‑314 print controller version 1.0, make sure that it is connected to the power outlet and has been calibrated and set according to the manufacturer's specifications. Connect the USB cable that is included with the X-Rite i1/iSis/ i1iO spectrophotometer to both the X-Rite i1/iSis/i1iO spectrophotometer and the USB port at the back of the IC‑314 print controller version 1.0. The first time the X-Rite i1/iSis/i1iO spectrophotometer is connected to the IC‑314 print controller version 1.0, the driver is installed automatically. When the driver installation successfully completes, you are ready to use the i1/iSis/i1iO spectrophotometer to create a calibration table. Using the X-Rite i1 spectrophotometer to create a calibration table Requirements: ● Your spectrophotometer must be connected to the USB port on the IC‑314 print controller version 1.0. The first time that you connect the device to the IC‑314 print controller version 1.0, you are notified that the driver is being installed. Wait for the driver installation to finish before proceeding further. ● Make sure that your spectrophotometer is calibrated by placing the spectrophotometer on its calibration plate. ● The Print queue must be ready for printing (not suspended), and the printer must be warmed up.